fix: behind a line breaker closed ahead of the pantographs the main circuit still needs the voltage

Review of #272. The closed line breaker used to mean there's traction
voltage, the undervoltage trip opening it without one. With
PantRequiresMain=Yes it closes on the battery and holds without voltage,
so everything that took Mains for "the main circuit is live" ran with the
pantographs down, lowered for a section, or under a dead catenary.

- MainCircuitPowered(): the line breaker closed, and on a vehicle with
  PantRequiresMain and current collectors also the voltage at least MinV
  (what the undervoltage trip takes). For every other vehicle it is Mains.
  It feeds the converter (and through it the 110 V and a compressor on
  it), a compressor on the main circuit, the heating from the main
  circuit, the motor blowers, the blowers of the starting resistors, the
  current of the series motors and the induction motor drive.
- The undervoltage relay of such a vehicle opens the line contactors, as
  the line breaker opening did elsewhere: the camshaft goes back to zero
  and the motors get no current, also not the generator current a closed
  circuit without voltage gave. The relay picks up again with the voltage
  back and the master controller at zero or the first position, so the
  start begins anew instead of the camshaft running back up to the
  position left on the controller.

Vehicles without the key are unchanged: the golden traces recorded before
the change compare exactly.
This commit is contained in:
jerrrrycho
2026-11-11 21:54:20 +01:00
parent c09c44f978
commit 226eaabb7b
3 changed files with 287 additions and 16 deletions

View File

@@ -2165,7 +2165,8 @@ class TMoverParameters
bool JointEngineStart{true};
// config, .fiz Cntrl.PantRequiresMain: the line breaker closes without traction voltage and holds without it, and the
// pantographs rise and stay up only while it's closed (EU05, EP05, ČD 181 family); off, the pantographs come first and the line
// breaker needs their voltage
// breaker needs their voltage. what the main circuit feeds still needs the voltage (MainCircuitPowered()), and without
// it the undervoltage relay opens the line contactors (NoVoltRelay)
bool PantographsRequireMains{false};
bool LineBreakerClosesOnlyAtNoPowerPos{false};
bool ControlPressureSwitch{false}; // activates if the main pipe and/or brake cylinder pressure aren't within operational levels
@@ -2232,7 +2233,9 @@ class TMoverParameters
double PantPress = 0.0; /*Cisnienie w zbiornikach pantografow*/
bool PantPressSwitchActive{false}; // state of the pantograph pressure switch. gets primed at defined pressure level in pantograph air system
bool PantPressLockActive{false}; // pwr system state flag. fires when pressure switch activates by pantograph pressure dropping below defined level
bool NoVoltRelay{true}; // switches off if the power level drops below threshold
// switches off if the power level drops below threshold, which opens the line breaker; with PantographsRequireMains
// it opens the line contactors instead, and switches back on only with the master controller at zero or the first position
bool NoVoltRelay{true};
bool OvervoltageRelay{true}; // switches off if the power level goes above threshold
bool s_CAtestebrake = false; // hunter-091012: zmienna dla testu ca
std::array<std::pair<double, double>, 4> PowerCircuits; // 24v, 110v, 3x400v and 3000v power circuits, voltage from local sources and current draw pairs
@@ -2661,6 +2664,11 @@ class TMoverParameters
bool HeatingSwitch(bool const State, range_t const Notify = range_t::consist);
void HeatingSwitch_(bool const State);
double EnginePowerSourceVoltage() const; // returns voltage of defined main engine power source
// whether the main circuit feeds what runs on it (the converter, a compressor, the heating, the motor and resistor
// blowers, the traction motors): the line breaker closed, and where it closes ahead of the pantographs and holds
// without traction voltage (PantographsRequireMains) also the voltage there, at least the one the undervoltage
// trip takes. everywhere else it's the same as Mains
bool MainCircuitPowered() const;