18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-19 09:56:01 +01:00

feat: SM42 vigilance device switched off in the shunt mode (eu07/maszyna#457)

The shunt mode of the diesel-electrics (ShuntMode=1: SM42, SP42, SU42) now
suspends their vigilance device (CA): no alerter while running, no alarm for the
button held too long, and an alarm already on goes out. The cab signalling (SHP)
stays as it was. Back in the line mode the CA works as before.
This commit is contained in:
jerrrrycho
2026-11-07 20:13:46 +01:00
parent a86bcb1ef5
commit 329dc4e42e
3 changed files with 59 additions and 4 deletions

View File

@@ -227,3 +227,38 @@ TEST_CASE("cab: the lamps and the buzzer of the security system left unattended"
CHECK(security.radiostop_available());
scenario.check();
}
TEST_CASE("cab: the SM42's vigilance device switched off in the shunt mode") {
// eu07/maszyna#457: the shunt mode of the SM42 switches its vigilance device (CA) off, it alerts again
// once the shunt mode is off
scenario scenario{"cab/sm42 vigilance in shunt mode", motion() + brakes(), test::track{}};
scenario.add("sm42_v1/6d1", 1);
REQUIRE(scenario.start_up());
auto &sm42{scenario.cab()};
auto const &security{sm42.SecuritySystem};
REQUIRE(sm42.CurrentSwitch(true));
REQUIRE(sm42.ShuntMode);
scenario.get_going();
sm42.AnPos = 0.3;
sm42.IncMainCtrl(1);
scenario.act("unattended in shunt mode");
bool blinked{false};
for (int i = 0; i < 120; ++i) {
scenario.train().run(1.0, scenario.line());
blinked |= security.is_blinking();
}
CHECK(sm42.Vel > 1.0);
CHECK_FALSE(blinked);
CHECK(sm42.PipePress > 3.5);
scenario.act("shunt mode off");
scenario.notch_back(0);
REQUIRE(sm42.CurrentSwitch(false));
sm42.IncMainCtrl(1);
scenario.act("unattended");
for (int i = 0; i < 120; ++i) {
scenario.train().run(1.0, scenario.line());
blinked |= security.is_vigilance_blinking();
}
CHECK(blinked);
scenario.check();
}