16
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-07-22 08:09:19 +02:00

compressor start method, minor ai vehicle preparation logic tweaks, minor refactoring

This commit is contained in:
tmj-fstate
2018-04-18 22:14:16 +02:00
parent fc1f57a5d4
commit 430ab99f8e
9 changed files with 86 additions and 72 deletions

View File

@@ -2679,7 +2679,7 @@ bool TMoverParameters::ConverterSwitch( bool State, int const Notify )
// *************************************************************************************************
bool TMoverParameters::CompressorSwitch( bool State, int const Notify )
{
if( CompressorPower > 1 ) {
if( CompressorStart != start::manual ) {
// only pay attention if the compressor can be controlled manually
return false;
}
@@ -3323,35 +3323,38 @@ void TMoverParameters::CompressorCheck(double dt)
else {
if( CompressorPower == 3 ) {
// experimental: make sure compressor coupled with diesel engine is always ready for work
CompressorAllow = true;
CompressorStart = start::automatic;
}
if (CompressorFlag) // jeśli sprężarka załączona
{ // sprawdzić możliwe warunki wyłączenia sprężarki
if (CompressorPower == 5) // jeśli zasilanie z sąsiedniego członu
{ // zasilanie sprężarki w członie ra z członu silnikowego (sprzęg 1)
if (Couplers[1].Connected != NULL)
CompressorFlag =
( Couplers[ 1 ].Connected->CompressorAllow
&& Couplers[ 1 ].Connected->CompressorAllowLocal
&& Couplers[ 1 ].Connected->Mains
&& Couplers[ 1 ].Connected->ConverterFlag );
else
CompressorFlag = false; // bez tamtego członu nie zadziała
if( Couplers[ side::rear ].Connected != NULL ) {
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Couplers[ side::rear ].Connected->ConverterFlag ) );
}
else {
// bez tamtego członu nie zadziała
CompressorFlag = false;
}
}
else if (CompressorPower == 4) // jeśli zasilanie z poprzedniego członu
{ // zasilanie sprężarki w członie ra z członu silnikowego (sprzęg 1)
if (Couplers[0].Connected != NULL)
CompressorFlag =
( Couplers[ 0 ].Connected->CompressorAllow
&& Couplers[ 0 ].Connected->CompressorAllowLocal
&& Couplers[ 0 ].Connected->Mains
&& Couplers[ 0 ].Connected->ConverterFlag );
else
if( Couplers[ side::front ].Connected != NULL ) {
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Couplers[ side::front ].Connected->ConverterFlag ) );
}
else {
CompressorFlag = false; // bez tamtego członu nie zadziała
}
}
else
CompressorFlag =
( ( CompressorAllow )
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Mains )
&& ( ( ConverterFlag )
@@ -3402,38 +3405,37 @@ void TMoverParameters::CompressorCheck(double dt)
// or if the switch is on and the pressure isn't maxed
if( CompressorPower == 5 ) // jeśli zasilanie z następnego członu
{ // zasilanie sprężarki w członie ra z członu silnikowego (sprzęg 1)
if( Couplers[ 1 ].Connected != nullptr ) {
CompressorFlag =
( Couplers[ 1 ].Connected->CompressorAllow
&& Couplers[ 1 ].Connected->CompressorAllowLocal
&& Couplers[ 1 ].Connected->Mains
&& Couplers[ 1 ].Connected->ConverterFlag );
}
if( Couplers[ side::rear ].Connected != NULL ) {
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Couplers[ side::rear ].Connected->ConverterFlag ) );
}
else {
CompressorFlag = false; // bez tamtego członu nie zadziała
// bez tamtego członu nie zadziała
CompressorFlag = false;
}
}
else if( CompressorPower == 4 ) // jeśli zasilanie z poprzedniego członu
{ // zasilanie sprężarki w członie ra z członu silnikowego (sprzęg 1)
if( Couplers[ 0 ].Connected != nullptr ) {
CompressorFlag =
( Couplers[ 0 ].Connected->CompressorAllow
&& Couplers[ 0 ].Connected->CompressorAllowLocal
&& Couplers[ 0 ].Connected->Mains
&& Couplers[ 0 ].Connected->ConverterFlag );
if( Couplers[ side::front ].Connected != NULL ) {
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Couplers[ side::front ].Connected->ConverterFlag ) );
}
else {
CompressorFlag = false; // bez tamtego członu nie zadziała
}
}
else {
CompressorFlag =
( ( CompressorAllow )
&& ( CompressorAllowLocal )
&& ( Mains )
&& ( ( ConverterFlag )
|| ( CompressorPower == 0 )
|| ( CompressorPower == 3 ) ) );
CompressorFlag = (
( ( CompressorAllow ) || ( CompressorStart == start::automatic ) )
&& ( CompressorAllowLocal )
&& ( Mains )
&& ( ( ConverterFlag )
|| ( CompressorPower == 0 )
|| ( CompressorPower == 3 ) ) );
}
// NOTE: crude way to enforce simultaneous activation of compressors in multi-unit setups
@@ -8143,6 +8145,19 @@ void TMoverParameters::LoadFIZ_Cntrl( std::string const &line ) {
}
extract_value( ConverterStartDelay, "ConverterStartDelay", line, "" );
// compressor
{
std::map<std::string, start> starts {
{ "Manual", start::manual },
{ "Automatic", start::automatic }
};
auto lookup = starts.find( extract_value( "CompressorStart", line ) );
CompressorStart =
lookup != starts.end() ?
lookup->second :
start::manual;
}
// fuel pump
{
std::map<std::string, start> starts {
@@ -9256,7 +9271,7 @@ bool TMoverParameters::RunCommand( std::string Command, double CValue1, double C
// end
else if (Command == "CompressorSwitch") /*NBMX*/
{
if( CompressorPower < 2 ) {
if( CompressorStart == start::manual ) {
CompressorAllow = ( CValue1 == 1 );
}
OK = SendCtrlToNext( Command, CValue1, CValue2, Couplertype );