mirror of
https://github.com/MaSzyna-EU07/maszyna.git
synced 2026-11-24 18:59:16 +01:00
feat: line breaker before the pantographs, Cntrl.PantRequiresMain (#68)
New optional .fiz key Cntrl.PantRequiresMain (default No, every existing vehicle unchanged). With Yes, as on Czech-built locomotives: - the line breaker closes on the low voltage circuits, without traction voltage, and the undervoltage trip doesn't open it (overvoltage and the other trips still do); - a pantograph valve opens and stays open only while the vehicle's line breaker is closed, so opening it drops the pantographs. The AI (TController::PrepareEngine) closes the line breaker before raising the pantographs for such a vehicle; the line breaker steps moved into TController::close_line_breaker(). test::start_up() follows the same order. Game data: to use it, PantRequiresMain=Yes goes on the Cntrl. line of dynamic/pkp/ep05_v2/ep05.fiz, ep05v1.fiz and dynamic/cd/181_v2/181_cz1.fiz, 18x_pl.fiz (left for later, not part of this change). (#68)
This commit is contained in:
@@ -2093,6 +2093,10 @@ class TMoverParameters
|
||||
double MainsInitTime{0.0}; // config, initialization time (in seconds) of the main circuit after it receives power, before it can be closed
|
||||
double MainsInitTimeCountdown{0.0}; // current state of main circuit initialization, remaining time (in seconds) until it's ready
|
||||
start_t MainsStart{start_t::manual};
|
||||
// config, .fiz Cntrl.PantRequiresMain: the line breaker closes without traction voltage and holds without it, and the
|
||||
// pantographs rise and stay up only while it's closed (Czech locomotives); off, the pantographs come first and the line
|
||||
// breaker needs their voltage
|
||||
bool PantographsRequireMains{false};
|
||||
bool LineBreakerClosesOnlyAtNoPowerPos{false};
|
||||
bool ControlPressureSwitch{false}; // activates if the main pipe and/or brake cylinder pressure aren't within operational levels
|
||||
bool HasControlPressureSwitch{true};
|
||||
|
||||
Reference in New Issue
Block a user