fix: a latching line breaker lever goes off with the breaker knocked out (#277)
The EP05's single two-state line breaker lever stayed on once the converter overload relay knocked the breaker out: every press of the toggle tried to close the open breaker, which the tripped relay refused. A press now puts a lever left on over an open breaker off first. (eu07/maszyna#394)
This commit is contained in:
114
tests/unit/test_linebreaker.cpp
Normal file
114
tests/unit/test_linebreaker.cpp
Normal file
@@ -0,0 +1,114 @@
|
||||
#include "stdafx.h"
|
||||
#include "doctest.h"
|
||||
#include "consist.h"
|
||||
#include "drive.h"
|
||||
|
||||
#include "vehicle/linebreaker.h"
|
||||
|
||||
// the line breaker (WS) controls of the cab (eu07/maszyna#394)
|
||||
|
||||
using test::consist;
|
||||
using test::definition;
|
||||
|
||||
namespace {
|
||||
|
||||
// the line breaker lever of the EP05 (main_sw), a single two-state lever, the way TTrain works it: the state
|
||||
// the cab keeps of the line breaker follows the vehicle, the breaker closes while the lever is on and can close
|
||||
struct lever {
|
||||
TMoverParameters &mover;
|
||||
int breaker{0}; // as TTrain::m_linebreakerstate: 0 open, 1 closed
|
||||
bool on{false};
|
||||
|
||||
void press() {
|
||||
switch (linebreaker::pressed(breaker, true, on)) {
|
||||
case linebreaker::toggle::close:
|
||||
on = true;
|
||||
break;
|
||||
case linebreaker::toggle::open:
|
||||
on = false;
|
||||
if (breaker == 1 && mover.MainSwitch(false)) {
|
||||
breaker = 0;
|
||||
}
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
// TTrain::Update()
|
||||
void update() {
|
||||
if (breaker == 0 && mover.Mains) {
|
||||
breaker = 1;
|
||||
}
|
||||
if (breaker == 1 && false == mover.Mains) {
|
||||
breaker = 0;
|
||||
}
|
||||
if (on && breaker == 0 && mover.MainSwitchCheck()) {
|
||||
breaker = mover.MainSwitch(true) ? 1 : 0;
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
} // namespace
|
||||
|
||||
TEST_CASE("line breaker: a press of the toggle closes an open breaker and opens a closed one") {
|
||||
using enum linebreaker::toggle;
|
||||
for (auto const latching : {false, true}) {
|
||||
CHECK(linebreaker::pressed(0, latching, false) == close);
|
||||
CHECK(linebreaker::pressed(1, latching, true) == open);
|
||||
CHECK(linebreaker::pressed(1, latching, false) == open);
|
||||
// freshly closed, the cab finishes closing it first
|
||||
CHECK(linebreaker::pressed(2, latching, true) == none);
|
||||
}
|
||||
// a lever left on over an open breaker goes off; push buttons have no position to keep
|
||||
CHECK(linebreaker::pressed(0, true, true) == open);
|
||||
CHECK(linebreaker::pressed(0, false, true) == close);
|
||||
}
|
||||
|
||||
TEST_CASE("line breaker: the EP05's lever goes off with the converter overload relay tripped (eu07/maszyna#394)") {
|
||||
consist train;
|
||||
auto &ep05{train.add(definition::fiz("ep05_v2/ep05"), 1).mover()};
|
||||
test::track const line{0.15, 0.0, test::catenary_3kv};
|
||||
auto const driver{test::driving(train)};
|
||||
REQUIRE(test::start_up(driver, line));
|
||||
REQUIRE(ep05.Mains);
|
||||
REQUIRE(ep05.ConverterFlag);
|
||||
lever ws{ep05, 1, true};
|
||||
|
||||
// the converter overload relay knocks the line breaker out, as the cab does it when the converter is
|
||||
// switched on together with the compressor; the lever stays on
|
||||
ep05.ConvOvldFlag = true;
|
||||
ep05.MainSwitch(false, range_t::local);
|
||||
ws.update();
|
||||
REQUIRE_FALSE(ep05.Mains);
|
||||
REQUIRE(ws.breaker == 0);
|
||||
CHECK(ws.on);
|
||||
// with the relay tripped the breaker doesn't close
|
||||
test::drive(driver, line, 5.0);
|
||||
CHECK_FALSE(ep05.MainSwitchCheck());
|
||||
|
||||
// nothing holds the lever: it goes off, and on again, though the breaker stays open
|
||||
ws.press();
|
||||
CHECK_FALSE(ws.on);
|
||||
ws.press();
|
||||
CHECK(ws.on);
|
||||
ws.update();
|
||||
CHECK_FALSE(ep05.Mains);
|
||||
ws.press();
|
||||
CHECK_FALSE(ws.on);
|
||||
|
||||
// the relay reset, with the converter switched off, the lever put on closes the breaker again
|
||||
ep05.ConverterSwitch(false, range_t::local);
|
||||
test::drive(driver, line, 1.0);
|
||||
CHECK(ep05.RelayReset(relay_t::primaryconverteroverload, range_t::local));
|
||||
CHECK_FALSE(ep05.ConvOvldFlag);
|
||||
ws.update();
|
||||
CHECK_FALSE(ep05.Mains); // the lever is off
|
||||
ws.press();
|
||||
ws.update();
|
||||
CHECK(ep05.Mains);
|
||||
CHECK(ws.breaker == 1);
|
||||
// and the next press opens it
|
||||
ws.press();
|
||||
CHECK_FALSE(ws.on);
|
||||
CHECK_FALSE(ep05.Mains);
|
||||
}
|
||||