generic cab control state indicators, ai master controller logic enhancements, battery charging for diesel powered vehicles workaround, water heater damage fix, ai route scanning fixes, material loading fix
This commit is contained in:
@@ -812,10 +812,13 @@ void TMoverParameters::UpdateBatteryVoltage(double dt)
|
||||
|
||||
// HACK: allow to draw power also from adjacent converter, applicable for EMUs
|
||||
// TODO: expand power cables system to include low voltage power transfers
|
||||
// HACK: emulate low voltage generator powered directly by the diesel engine
|
||||
auto const converteractive{ (
|
||||
( ConverterFlag )
|
||||
|| ( ( ( Couplers[ side::front ].CouplingFlag & coupling::permanent ) != 0 ) && Couplers[ side::front ].Connected->ConverterFlag )
|
||||
|| ( ( ( Couplers[ side::rear ].CouplingFlag & coupling::permanent ) != 0 ) && Couplers[ side::rear ].Connected->ConverterFlag ) ) };
|
||||
|| ( ( ( Couplers[ side::rear ].CouplingFlag & coupling::permanent ) != 0 ) && Couplers[ side::rear ].Connected->ConverterFlag ) )
|
||||
|| ( ( EngineType == TEngineType::DieselElectric ) && ( true == Mains ) )
|
||||
|| ( ( EngineType == TEngineType::DieselEngine ) && ( true == Mains ) ) };
|
||||
|
||||
if ((NominalBatteryVoltage / BatteryVoltage < 1.22) && Battery)
|
||||
{ // 110V
|
||||
@@ -1529,18 +1532,18 @@ void TMoverParameters::WaterPumpCheck( double const Timestep ) {
|
||||
// water heater status check
|
||||
void TMoverParameters::WaterHeaterCheck( double const Timestep ) {
|
||||
|
||||
WaterHeater.is_damaged = (
|
||||
( true == WaterHeater.is_damaged )
|
||||
|| ( ( true == WaterHeater.is_active )
|
||||
&& ( false == WaterPump.is_active ) ) );
|
||||
|
||||
WaterHeater.is_active = (
|
||||
( false == WaterHeater.is_damaged )
|
||||
&& ( true == Battery )
|
||||
&& ( true == WaterHeater.is_enabled )
|
||||
&& ( true == WaterHeater.breaker )
|
||||
&& ( ( WaterHeater.is_active ) || ( WaterHeater.config.temp_min < 0 ) || ( dizel_heat.temperatura1 < WaterHeater.config.temp_min ) ) );
|
||||
|
||||
|
||||
WaterHeater.is_damaged = (
|
||||
( true == WaterHeater.is_damaged )
|
||||
|| ( ( true == WaterHeater.is_active )
|
||||
&& ( false == WaterPump.is_active ) ) );
|
||||
|
||||
if( ( WaterHeater.config.temp_max > 0 )
|
||||
&& ( dizel_heat.temperatura1 > WaterHeater.config.temp_max ) ) {
|
||||
WaterHeater.is_active = false;
|
||||
@@ -6664,7 +6667,7 @@ TMoverParameters::AssignLoad( std::string const &Name, float const Amount ) {
|
||||
for( auto const &loadattributes : LoadAttributes ) {
|
||||
if( Name == loadattributes.name ) {
|
||||
LoadType = loadattributes;
|
||||
LoadAmount = Amount;
|
||||
LoadAmount = clamp( Amount, 0.f, MaxLoad ) ;
|
||||
return true;
|
||||
}
|
||||
}
|
||||
@@ -6702,7 +6705,7 @@ bool TMoverParameters::LoadingDone(double const LSpeed, std::string const &Loadn
|
||||
if( ( LoadAmount <= 0 ) || ( CommandIn.Value1 <= 0 ) ) {
|
||||
// pusto lub rozładowano żądaną ilość
|
||||
LoadStatus = 4; // skończony rozładunek
|
||||
LoadAmount = std::max( 0.f, LoadAmount ); //ładunek nie może być ujemny
|
||||
LoadAmount = clamp( LoadAmount, 0.f, MaxLoad); //ładunek nie może być ujemny
|
||||
}
|
||||
if( LoadAmount == 0.f ) {
|
||||
AssignLoad(""); // jak nic nie ma, to nie ma też nazwy
|
||||
|
||||