18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-23 17:19:14 +01:00

Merge pull request #278 from MaSzyna-EU07/feat/shunt-lock-resistive

Field shunting locked at zero and on resistive positions (eu07/maszyna#402)
This commit is contained in:
2026-11-09 12:53:57 +00:00
committed by GitHub
4 changed files with 172 additions and 3 deletions

View File

@@ -1987,6 +1987,7 @@ class TMoverParameters
double MirrorVelClose{5.0};
bool MirrorForbidden{false}; /*czy jest pozwolenie na otworzenie lusterek (przycisk)*/
bool ScndS = false; /*Czy jest bocznikowanie na szeregowej*/
bool ScndCtrlResistiveLock{false}; // the shunt controller can't be moved, up or down, while the master controller is at zero or on a resistive position, and drops to 0 when the master controller gets there (ScndCtrlResistiveLock=Yes in Cntrl.)
bool SpeedCtrl = false; /*czy jest tempomat*/
speed_control SpeedCtrlUnit; /*parametry tempomatu*/
double SpeedCtrlButtons[10]{30, 40, 50, 60, 70, 80, 90, 100, 110, 120}; /*przyciski prędkości*/
@@ -2430,6 +2431,11 @@ class TMoverParameters
bool IncScndCtrl(int CtrlSpeed);
bool DecScndCtrl(int CtrlSpeed);
int GetVirtualScndPos() const;
// whether ScndCtrlResistiveLock keeps the shunt controller from being moved at the current master controller position
bool IsScndCtrlLockedByMainCtrl() const;
// ScndCtrlResistiveLock: the shunt controller drops to 0 once the master controller is at zero or on a resistive position, so it
// can't stay engaged there, locked in place (eu07/maszyna#402)
void ScndCtrlResistiveLockCheck();
bool IsScndCtrlNoPowerPos() const;
bool IsScndCtrlMaxPowerPos() const;

View File

@@ -1698,6 +1698,8 @@ void TMoverParameters::compute_movement_(double const Deltatime)
BRVentilators = false;
}
// the master controller set directly, not through IncMainCtrl()/DecMainCtrl() (AI, consist): the locked shunt follows it as well
ScndCtrlResistiveLockCheck();
// automatyczny rozruch
if (EngineType == TEngineType::ElectricSeriesMotor && AutoRelayCheck())
{
@@ -2604,6 +2606,7 @@ bool TMoverParameters::IncMainCtrl(int CtrlSpeed)
if (true == OK)
{
ScndCtrlResistiveLockCheck(); // e.g. from the last series position on to the resistive parallel ones
SendCtrlToNext("MainCtrl", MainCtrlPos, CabActive); //???
SendCtrlToNext("ScndCtrl", ScndCtrlPos, CabActive);
}
@@ -2729,6 +2732,7 @@ bool TMoverParameters::DecMainCtrl(int CtrlSpeed)
if (OK)
{
ScndCtrlResistiveLockCheck(); // the shunt drops when the master controller leaves a resistance-free position
/*OK:=*/SendCtrlToNext("MainCtrl", MainCtrlPos, CabActive); // hmmmm...???!!!
/*OK:=*/SendCtrlToNext("ScndCtrl", ScndCtrlPos, CabActive);
}
@@ -2818,7 +2822,7 @@ bool TMoverParameters::IncScndCtrl(int CtrlSpeed)
{
// if (RList[MainCtrlPos].R=0) and (MainCtrlPos>0) and (ScndCtrlPos<ScndCtrlPosNo) and
// (not CoupledCtrl) then
if (ScndCtrlPos < ScndCtrlPosNo && !CoupledCtrl)
if (ScndCtrlPos < ScndCtrlPosNo && !CoupledCtrl && !IsScndCtrlLockedByMainCtrl())
{
// TBD, TODO: refactor this validation as part of relay check routine (currently in tractionforce()
// TBD, TODO: diesel electric engine utilize scndctrlactualpos like the other types?
@@ -2889,7 +2893,7 @@ bool TMoverParameters::DecScndCtrl(int CtrlSpeed)
}
else if (ScndCtrlPosNo > 0 && CabActive != 0)
{
if (ScndCtrlPos > 0 && !CoupledCtrl && (EngineType != TEngineType::DieselElectric || !AutoRelayFlag))
if (ScndCtrlPos > 0 && !CoupledCtrl && (EngineType != TEngineType::DieselElectric || !AutoRelayFlag) && !IsScndCtrlLockedByMainCtrl())
{
if (CtrlSpeed == 1)
{
@@ -2939,6 +2943,22 @@ bool TMoverParameters::DecScndCtrl(int CtrlSpeed)
return OK;
}
bool TMoverParameters::IsScndCtrlLockedByMainCtrl() const
{
// ET21, ET22, EP09: the field shunting engages only on the resistance-free positions of the master controller (eu07/maszyna#402)
return ScndCtrlResistiveLock && (IsMainCtrlNoPowerPos() || RList[MainCtrlPos].R >= 0.01);
}
void TMoverParameters::ScndCtrlResistiveLockCheck()
{
// the shunt controller, locked in both directions on zero and the resistive positions, would otherwise stay engaged there once the
// master controller is taken back (or set from elsewhere, e.g. by the AI or another vehicle of the consist) with the shunt on
if (ScndCtrlPos > 0 && !CoupledCtrl && IsScndCtrlLockedByMainCtrl())
{
ScndCtrlPos = 0;
}
}
int TMoverParameters::GetVirtualScndPos() const
{
if (TrainType == dt_ET42 && DynamicBrakeFlag && !ScndCtrlPos)
@@ -11105,6 +11125,7 @@ void TMoverParameters::LoadFIZ_Cntrl(std::string const &line)
extract_value(EIMCtrlEmergency, "EIMCtrlEmergency", line, "");
extract_value(ScndS, "ScndS", line, ""); // brak pozycji rownoleglej przy niskiej nastawie PSR
extract_value(ScndCtrlResistiveLock, "ScndCtrlResistiveLock", line, ""); // bocznikowanie tylko na pozycjach bezoporowych
extract_value(InitialCtrlDelay, "IniCDelay", line, "");
extract_value(CtrlDelay, "SCDelay", line, "");

View File

@@ -37,3 +37,145 @@ TEST_CASE("cntrl: the relays of a multiple unit start on their own, of other veh
CHECK(unit->ConverterOverloadRelayStart == start_t::automatic);
}
}
namespace {
// the first position of the master controller after Position without the starting resistors in the circuit
int resistance_free_position(TMoverParameters const &Vehicle, int Position = 0) {
for (auto position{Position + 1}; position <= Vehicle.MainCtrlPosNo; ++position) {
if (Vehicle.RList[position].R < 0.01) {
return position;
}
}
return 0;
}
// the vehicle with its cab occupied, the master controller set to Position and the shunt controller off
void controllers_at(vehicle &Vehicle, int Position) {
Vehicle->CabActive = 1;
Vehicle->MainCtrlPos = Position;
Vehicle->ScndCtrlPos = 0;
}
} // namespace
TEST_CASE("cntrl: ScndCtrlResistiveLock keeps the field shunting off at zero and on the resistive positions (eu07/maszyna#402)") {
for (auto const *path : {"et22_v3/201e-rn", "ep09_v2/104e"}) {
CAPTURE(path);
vehicle locked{definition::fiz(path).set("Cntrl", "ScndCtrlResistiveLock", "Yes"), 0.0, "test", 1};
REQUIRE(locked->ScndCtrlResistiveLock);
REQUIRE(locked->ScndCtrlPosNo > 0);
auto const resistancefree{resistance_free_position(locked.mover())};
REQUIRE(resistancefree > 1);
if (resistancefree <= 1) {
continue; // not reached, the REQUIRE above ends the test; tells the static analysis the index below is in range
}
REQUIRE(locked->RList[resistancefree - 1].R >= 0.01);
SUBCASE("zero") {
controllers_at(locked, 0);
CHECK(locked->IsScndCtrlLockedByMainCtrl());
CHECK_FALSE(locked->IncScndCtrl(1));
CHECK_FALSE(locked->IncScndCtrl(2));
CHECK(locked->ScndCtrlPos == 0);
}
SUBCASE("resistive positions") {
for (auto position{1}; position < resistancefree; ++position) {
CAPTURE(position);
controllers_at(locked, position);
CHECK_FALSE(locked->IncScndCtrl(1));
CHECK(locked->ScndCtrlPos == 0);
}
}
SUBCASE("every resistance-free position") {
for (auto position{resistancefree}; position > 0; position = resistance_free_position(locked.mover(), position)) {
CAPTURE(position);
controllers_at(locked, position);
CHECK_FALSE(locked->IsScndCtrlLockedByMainCtrl());
CHECK(locked->IncScndCtrl(1));
CHECK(locked->ScndCtrlPos == 1);
}
}
SUBCASE("the shunt goes down on a resistance-free position") {
controllers_at(locked, resistancefree);
REQUIRE(locked->IncScndCtrl(1));
REQUIRE(locked->IncScndCtrl(1));
CHECK(locked->DecScndCtrl(1));
CHECK(locked->ScndCtrlPos == 1);
CHECK(locked->DecScndCtrl(2));
CHECK(locked->ScndCtrlPos == 0);
}
SUBCASE("the shunt doesn't go down on a resistive position either") {
// a state the lock doesn't let arise (see below), set by hand to check the controller alone
controllers_at(locked, resistancefree - 1);
locked->ScndCtrlPos = 1;
CHECK(locked->IsScndCtrlLockedByMainCtrl());
CHECK_FALSE(locked->DecScndCtrl(1));
CHECK_FALSE(locked->DecScndCtrl(2));
CHECK(locked->ScndCtrlPos == 1);
}
SUBCASE("the master controller taken back from a shunt step drops the shunt") {
controllers_at(locked, resistancefree);
REQUIRE(locked->IncScndCtrl(1));
if (locked->TrainType == dt_ET22) {
// the ET22's master controller doesn't turn with the shunt on: the shunt goes off first, as before
CHECK_FALSE(locked->DecMainCtrl(1));
CHECK(locked->MainCtrlPos == resistancefree);
CHECK(locked->DecScndCtrl(1));
}
CHECK(locked->DecMainCtrl(1));
CHECK(locked->MainCtrlPos == resistancefree - 1);
CHECK(locked->ScndCtrlPos == 0);
// and the master controller goes on down to zero, nothing left locked
while (locked->MainCtrlPos > 0 && locked->DecMainCtrl(1)) {
}
CHECK(locked->MainCtrlPos == 0);
}
SUBCASE("the master controller set directly (AI, consist) drops the shunt in the next update") {
controllers_at(locked, resistancefree);
REQUIRE(locked->IncScndCtrl(1));
locked->MainCtrlPos = resistancefree - 1;
locked.step();
CHECK(locked->ScndCtrlPos == 0);
CHECK(locked->MainCtrlPos == resistancefree - 1);
}
SUBCASE("the master controller moved up from a shunt step onto a resistive position drops the shunt") {
// the last series position, followed by the resistive parallel ones
auto lastseries{0};
for (auto position{resistancefree}; position > 0 && position < locked->MainCtrlPosNo; position = resistance_free_position(locked.mover(), position)) {
if (locked->RList[position + 1].R >= 0.01) {
lastseries = position;
break;
}
}
REQUIRE(lastseries > 0);
controllers_at(locked, lastseries);
locked->DirActive = 1;
REQUIRE(locked->IncScndCtrl(1));
if (locked->TrainType == dt_ET22) {
CHECK_FALSE(locked->IncMainCtrl(1)); // the ET22's interlock, as before
CHECK(locked->ScndCtrlPos == 1);
}
else {
CHECK(locked->IncMainCtrl(1));
CHECK(locked->MainCtrlPos == lastseries + 1);
CHECK(locked->ScndCtrlPos == 0);
}
}
}
}
TEST_CASE("cntrl: without ScndCtrlResistiveLock the field shunting engages on any position, as before") {
for (auto const *path : {"et22_v3/201e-rn", "ep09_v2/104e"}) {
CAPTURE(path);
vehicle unlocked{definition::fiz(path), 0.0, "test", 1};
CHECK_FALSE(unlocked->ScndCtrlResistiveLock);
for (auto const position : {0, 1}) {
CAPTURE(position);
controllers_at(unlocked, position);
CHECK_FALSE(unlocked->IsScndCtrlLockedByMainCtrl());
CHECK(unlocked->IncScndCtrl(1));
CHECK(unlocked->ScndCtrlPos == 1);
}
}
}

View File

@@ -3472,7 +3472,7 @@ bool TController::IncSpeed()
mvOccupied->Vel <= (IsCargoTrain ? 40 : 30) + (seriesmodefieldshunting ? 5 : 0) - (fAccGravity < -0.025 ? 10 : 0));
// when not in series mode use the first available parallel mode configuration until 50/60 km/h for passenger/cargo train
// (if there's only one parallel mode configuration it'll be used regardless of current speed)
auto const usefieldshunting = mvControlling->StLinFlag && mvControlling->RList[mvControlling->MainCtrlPos].R < 0.01 &&
auto const usefieldshunting = mvControlling->StLinFlag && mvControlling->RList[mvControlling->MainCtrlPos].R < 0.01 && false == mvControlling->IsScndCtrlLockedByMainCtrl() &&
(useseriesmode ? mvControlling->RList[mvControlling->MainCtrlPos].Bn == 1 :
true == sufficientacceleration && true == sufficienttractionforce && mvOccupied->Vel <= (IsCargoTrain ? 60 : 50) + (parallelmodefieldshunting ? 5 : 0) ?
mvControlling->RList[mvControlling->MainCtrlPos].Bn > 1 :