feat: lock the field shunting in both directions on resistive positions
With ScndCtrlResistiveLock=Yes the shunt controller can't be moved down either while the master controller is at zero or on a resistive position (eu07/maszyna#402: "inc/dec"). So that a shunt step can't be left stuck there, the shunt controller drops to 0 whenever the master controller is at zero or on a resistive position: right after IncMainCtrl()/DecMainCtrl() move it there (before the positions go down the consist) and in every update, for the master controller set directly (AI clamp, consist). Electrically nothing changes, the relays already drop the shunting on resistive positions. Reducing power is never blocked: the EP09/ET21 master controller turns back with the shunt on, the ET22 keeps its interlock (shunt off first), and on the ET22 a shunt left on at a resistive position would otherwise lock both controllers. Tests: the shunt goes down on resistance-free positions only; the master controller taken back or up onto a resistive position from a shunt step, by hand and directly, on the ET22 and EP09.
This commit is contained in:
@@ -96,12 +96,71 @@ TEST_CASE("cntrl: ScndCtrlResistiveLock keeps the field shunting off at zero and
|
||||
CHECK(locked->ScndCtrlPos == 1);
|
||||
}
|
||||
}
|
||||
SUBCASE("the shunting still goes off on a resistive position") {
|
||||
SUBCASE("the shunt goes down on a resistance-free position") {
|
||||
controllers_at(locked, resistancefree);
|
||||
REQUIRE(locked->IncScndCtrl(1));
|
||||
REQUIRE(locked->IncScndCtrl(1));
|
||||
CHECK(locked->DecScndCtrl(1));
|
||||
CHECK(locked->ScndCtrlPos == 1);
|
||||
CHECK(locked->DecScndCtrl(2));
|
||||
CHECK(locked->ScndCtrlPos == 0);
|
||||
}
|
||||
SUBCASE("the shunt doesn't go down on a resistive position either") {
|
||||
// a state the lock doesn't let arise (see below), set by hand to check the controller alone
|
||||
controllers_at(locked, resistancefree - 1);
|
||||
locked->ScndCtrlPos = 1;
|
||||
CHECK(locked->IsScndCtrlLockedByMainCtrl());
|
||||
CHECK_FALSE(locked->DecScndCtrl(1));
|
||||
CHECK_FALSE(locked->DecScndCtrl(2));
|
||||
CHECK(locked->ScndCtrlPos == 1);
|
||||
}
|
||||
SUBCASE("the master controller taken back from a shunt step drops the shunt") {
|
||||
controllers_at(locked, resistancefree);
|
||||
REQUIRE(locked->IncScndCtrl(1));
|
||||
if (locked->TrainType == dt_ET22) {
|
||||
// the ET22's master controller doesn't turn with the shunt on: the shunt goes off first, as before
|
||||
CHECK_FALSE(locked->DecMainCtrl(1));
|
||||
CHECK(locked->MainCtrlPos == resistancefree);
|
||||
CHECK(locked->DecScndCtrl(1));
|
||||
}
|
||||
CHECK(locked->DecMainCtrl(1));
|
||||
CHECK(locked->MainCtrlPos == resistancefree - 1);
|
||||
CHECK(locked->ScndCtrlPos == 0);
|
||||
// and the master controller goes on down to zero, nothing left locked
|
||||
while (locked->MainCtrlPos > 0 && locked->DecMainCtrl(1)) {
|
||||
}
|
||||
CHECK(locked->MainCtrlPos == 0);
|
||||
}
|
||||
SUBCASE("the master controller set directly (AI, consist) drops the shunt in the next update") {
|
||||
controllers_at(locked, resistancefree);
|
||||
REQUIRE(locked->IncScndCtrl(1));
|
||||
locked->MainCtrlPos = resistancefree - 1;
|
||||
CHECK(locked->DecScndCtrl(1));
|
||||
locked.step();
|
||||
CHECK(locked->ScndCtrlPos == 0);
|
||||
CHECK(locked->MainCtrlPos == resistancefree - 1);
|
||||
}
|
||||
SUBCASE("the master controller moved up from a shunt step onto a resistive position drops the shunt") {
|
||||
// the last series position, followed by the resistive parallel ones
|
||||
auto lastseries{0};
|
||||
for (auto position{resistancefree}; position > 0 && position < locked->MainCtrlPosNo; position = resistance_free_position(locked.mover(), position)) {
|
||||
if (locked->RList[position + 1].R >= 0.01) {
|
||||
lastseries = position;
|
||||
break;
|
||||
}
|
||||
}
|
||||
REQUIRE(lastseries > 0);
|
||||
controllers_at(locked, lastseries);
|
||||
locked->DirActive = 1;
|
||||
REQUIRE(locked->IncScndCtrl(1));
|
||||
if (locked->TrainType == dt_ET22) {
|
||||
CHECK_FALSE(locked->IncMainCtrl(1)); // the ET22's interlock, as before
|
||||
CHECK(locked->ScndCtrlPos == 1);
|
||||
}
|
||||
else {
|
||||
CHECK(locked->IncMainCtrl(1));
|
||||
CHECK(locked->MainCtrlPos == lastseries + 1);
|
||||
CHECK(locked->ScndCtrlPos == 0);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue