diff --git a/McZapkie/MOVER.h b/McZapkie/MOVER.h
index 91415ca1d..b619ba7de 100644
--- a/McZapkie/MOVER.h
+++ b/McZapkie/MOVER.h
@@ -301,6 +301,16 @@ enum class operation_t
/// Disable button release transition.
disable_off,
};
+/// What else the line contactors of a vehicle need before they can close (LineContactorsInterlock in the Cntrl. section).
+enum class line_contactors_interlock
+{
+ /// Nothing more, the legacy behaviour.
+ none,
+ /// The converter of the vehicle itself running, where it drives the traction motor fans (ET42).
+ converter,
+ /// The traction motor blowers of the vehicle running.
+ motor_blowers
+};
/// Auto-start method for ancillary devices (mutually exclusive).
enum class start_t
{
@@ -2229,6 +2239,8 @@ class TMoverParameters
start_t GroundRelayStart{start_t::manual}; // relay activation method
bool StLinFlag = false; /*!o styczniki liniowe*/
bool StLinSwitchOff{false}; // state of the button forcing motor connectors open
+ line_contactors_interlock LineContactorsInterlock{line_contactors_interlock::none}; // what else the line contactors need to close
+ double LouvresOpenPressure{5.0}; // main reservoir pressure [bar] at which the pneumatic louvres of the motor fans open (ET22)
bool ResistorsFlag = false; /*!o jazda rezystorowa*/
double RventRot = 0.0; /*!s obroty wentylatorow rozruchowych*/
double PantographVoltage{0.0}; // voltage supplied to pantographs
@@ -2613,6 +2625,19 @@ class TMoverParameters
{
return JointEngineStart ? range_t::consist : range_t::local;
}
+ // whether the pneumatic louvres of the motor fans are still closed, the main reservoir short of the pressure that opens them
+ bool LouvresClosed() const
+ {
+ return Compressor < LouvresOpenPressure;
+ }
+ // whether the devices the line contactors are interlocked with (LineContactorsInterlock) let them close
+ bool LineContactorsInterlockReleased() const;
+ // whether the line contactors wait for the converter of the vehicle, switched off with its local switch (converterlocal_sw).
+ // the AI driver doesn't leave it so: the converters of the other vehicles running, it would wait for the contactors forever
+ bool LineContactorsHeldByLocalConverterSwitch() const
+ {
+ return LineContactorsInterlock == line_contactors_interlock::converter && false == ConverterAllowLocal;
+ }
// whether the vehicle has a driver's cab: it has the driver's brake valve (BrakeHandle in the Cntrl. section of the
// .fiz), which the wagons and most cars of the units without a cab don't (a few copy the Cntrl. section of the cab
// car, as the EN57 s car does). it's the vehicle type's, unlike the cab the scenario puts a driver in
@@ -2683,6 +2708,8 @@ class TMoverParameters
void FuelPumpCheck(double const Timestep);
void OilPumpCheck(double const Timestep);
void MotorBlowersCheck(double const Timestep);
+ // whether the circuit a traction motor blower runs off has power: the battery, the converter or the main circuit, by its start type
+ bool MotorBlowerPowerIsAvailable(cooling_fan const &Blower) const;
void PantographsCheck(double const Timestep);
void LightsCheck(double const Timestep);
bool FuseOn(range_t const Notify = range_t::consist); // bezpiecznik nadamiary
diff --git a/McZapkie/Mover.cpp b/McZapkie/Mover.cpp
index de7f6e0dd..825137675 100644
--- a/McZapkie/Mover.cpp
+++ b/McZapkie/Mover.cpp
@@ -2406,9 +2406,7 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
}
blower.is_active =
// TODO: bind properly power source when ld is in place
- (blower.start_type == start_t::battery ? Power24vIsAvailable :
- blower.start_type == start_t::converter ? Power110vIsAvailable :
- MainCircuitPowered()) // power source
+ MotorBlowerPowerIsAvailable(blower) // power source
// breaker condition disabled until it's implemented in the class data
// && ( true == blower.breaker )
&& false == disable &&
@@ -2438,6 +2436,19 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
}
}
+bool TMoverParameters::MotorBlowerPowerIsAvailable(cooling_fan const &Blower) const
+{
+ switch (Blower.start_type)
+ {
+ case start_t::battery:
+ return Power24vIsAvailable;
+ case start_t::converter:
+ return Power110vIsAvailable;
+ default:
+ return MainCircuitPowered();
+ }
+}
+
void TMoverParameters::PantographsCheck(double const /*Timestep*/)
{
using enum start_t;
@@ -7529,7 +7540,30 @@ bool TMoverParameters::MotorConnectorsCheck()
auto const connectorsoff{false == Mains || undervoltage || true == FuseFlag || true == StLinSwitchOff || DirActive == 0};
- return false == connectorsoff;
+ return false == connectorsoff && LineContactorsInterlockReleased();
+}
+
+bool TMoverParameters::LineContactorsInterlockReleased() const
+{
+ switch (LineContactorsInterlock)
+ {
+ case line_contactors_interlock::converter:
+ // the converter of this very vehicle, not the 110 V of the trainset: a section with its fans off doesn't start
+ return ConverterFlag;
+ case line_contactors_interlock::motor_blowers:
+ return std::ranges::all_of(MotorBlowers, [this](auto const &Blower) {
+ if (Blower.min_start_velocity < 0)
+ {
+ return Blower.is_active;
+ }
+ // a blower which starts with the speed and the motor current (MotorBlowersStartVelocity) can't run before
+ // the contactors close, nor after a stop longer than it keeps running for: it's enough that it's
+ // switched on and has power, so it starts once the vehicle moves
+ return MotorBlowerPowerIsAvailable(Blower) && false == Blower.is_disabled && (Blower.start_type == start_t::manual ? Blower.is_enabled : true);
+ });
+ default:
+ return true;
+ }
}
bool TMoverParameters::OperatePantographsValve(operation_t const State, range_t const Notify)
@@ -11675,6 +11709,14 @@ void TMoverParameters::LoadFIZ_Cntrl(std::string const &line)
MotorBlowers[end::rear].start_type = lookup != starts.end() ? lookup->second : start_t::manual;
MotorBlowers[end::front].start_type = MotorBlowers[end::rear].start_type;
}
+ // what else the line contactors need to close
+ {
+ std::map> const interlocks{{"Converter", line_contactors_interlock::converter},
+ {"MotorBlowers", line_contactors_interlock::motor_blowers}};
+ auto lookup = interlocks.find(extract_value("LineContactorsInterlock", line));
+ LineContactorsInterlock = lookup != interlocks.end() ? lookup->second : line_contactors_interlock::none;
+ }
+ extract_value(LouvresOpenPressure, "LouvresOpenPressure", line, "");
// compartment lights
{
auto lookup = starts.find(extract_value("CompartmentLightsStart", line));
diff --git a/application/driverhints.cpp b/application/driverhints.cpp
index ae39ede7a..0c6f02cc8 100644
--- a/application/driverhints.cpp
+++ b/application/driverhints.cpp
@@ -326,6 +326,14 @@ TController::cue_action( driver_hint const Action, float const Actionparameter )
case driver_hint::converteron: {
if( AIControllFlag ) {
mvOccupied->ConverterSwitch( true );
+ // the local switch of the converter too, where the line contactors wait for the vehicle's own converter
+ // (LineContactorsInterlock): left off by the human driver, that vehicle would never take power
+ pVehicle->for_each(
+ coupling::control,
+ []( TDynamicObject * Vehicle ) {
+ auto *vehicle { Vehicle->MoverParameters };
+ if( vehicle->LineContactorsHeldByLocalConverterSwitch() ) {
+ vehicle->ConverterAllowLocal = true; } } );
}
remove_hint( driver_hint::converteroff );
hint(
diff --git a/tests/unit/test_line_contactors_interlock.cpp b/tests/unit/test_line_contactors_interlock.cpp
new file mode 100644
index 000000000..a025d4a69
--- /dev/null
+++ b/tests/unit/test_line_contactors_interlock.cpp
@@ -0,0 +1,315 @@
+#include "stdafx.h"
+#include "doctest.h"
+#include "consist.h"
+#include "drive.h"
+#include "vehicle.h"
+
+#include "McZapkie/hamulce.h"
+
+// the line contactors interlocked with the fans of the traction motors (eu07/maszyna#460): on the ET42 the fans of a
+// section run off its own converter, and with them switched off the line contactors of that section don't close.
+// the louvres of the fans of the ET22 open with the air of the main reservoir (eu07/maszyna#451)
+
+using test::definition;
+using test::vehicle;
+
+namespace {
+
+// a vehicle whose line contactors could close, but for the interlock
+vehicle ready(std::string_view const Interlock) {
+ auto loaded{definition::load("wagon")};
+ if (false == Interlock.empty()) {
+ loaded.set("Cntrl", "LineContactorsInterlock", std::string{Interlock});
+ }
+ vehicle locomotive{loaded};
+ locomotive->Mains = true;
+ locomotive->DirActive = 1;
+ locomotive->PipePress = 5.0;
+ locomotive->BrakePress = 0.0;
+ return locomotive;
+}
+
+test::track const line{0.15, 0.0, test::catenary_3kv};
+
+} // namespace
+
+TEST_CASE("line contactors interlock: read from the Cntrl. section, none by default") {
+ CHECK(ready("")->LineContactorsInterlock == line_contactors_interlock::none);
+ CHECK(ready("Converter")->LineContactorsInterlock == line_contactors_interlock::converter);
+ CHECK(ready("MotorBlowers")->LineContactorsInterlock == line_contactors_interlock::motor_blowers);
+ CHECK(ready("Something")->LineContactorsInterlock == line_contactors_interlock::none);
+}
+
+TEST_CASE("line contactors interlock: without one the converter and the blowers don't matter, as before") {
+ auto locomotive{ready("")};
+ locomotive->ConverterFlag = false;
+ for (auto &blower : locomotive->MotorBlowers) {
+ blower.is_active = false;
+ }
+ CHECK(locomotive->MotorConnectorsCheck());
+}
+
+TEST_CASE("line contactors interlock: on the converter, they close only with the vehicle's own converter running") {
+ auto locomotive{ready("Converter")};
+ locomotive->ConverterFlag = false;
+ locomotive->Power110vIsAvailable = true; // the 110 V from the other section doesn't run this one's fans
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ locomotive->ConverterFlag = true;
+ CHECK(locomotive->MotorConnectorsCheck());
+ locomotive->Mains = false; // the other conditions still hold
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+}
+
+TEST_CASE("line contactors interlock: on the motor blowers, they close only with all of them running") {
+ auto locomotive{ready("MotorBlowers")};
+ locomotive->MotorBlowers[end::front].is_active = true;
+ locomotive->MotorBlowers[end::rear].is_active = false;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ locomotive->MotorBlowers[end::rear].is_active = true;
+ CHECK(locomotive->MotorConnectorsCheck());
+}
+
+// a blower with MotorBlowersStartVelocity starts with the speed and the motor current, so it can't be running before
+// the line contactors close, nor after a stop longer than it keeps running for (MotorBlowersSustainTime): the interlock
+// takes it switched on and powered instead, or the vehicle would never take power
+
+TEST_CASE("line contactors interlock: a blower starting with the speed needs to be switched on and powered, not running") {
+ auto locomotive{ready("MotorBlowers")};
+ for (auto &blower : locomotive->MotorBlowers) {
+ blower.min_start_velocity = 5.f;
+ blower.is_enabled = true; // switched on by the driver
+ blower.is_active = false; // the vehicle stands
+ }
+ REQUIRE(locomotive->MotorBlowers[end::front].start_type == start_t::manual);
+ CHECK(locomotive->MotorConnectorsCheck());
+
+ auto &rear{locomotive->MotorBlowers[end::rear]};
+ SUBCASE("switched off, it holds the contactors open") {
+ rear.is_disabled = true;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ }
+ SUBCASE("not switched on, it holds the contactors open") {
+ rear.is_enabled = false;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ }
+ SUBCASE("off the converter, it needs the 110 V") {
+ rear.start_type = start_t::converter;
+ rear.is_enabled = false; // nothing for the driver to switch on
+ locomotive->Power110vIsAvailable = false;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ locomotive->Power110vIsAvailable = true;
+ CHECK(locomotive->MotorConnectorsCheck());
+ }
+ SUBCASE("off the battery, it needs the 24 V") {
+ rear.start_type = start_t::battery;
+ locomotive->Power24vIsAvailable = false;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ locomotive->Power24vIsAvailable = true;
+ CHECK(locomotive->MotorConnectorsCheck());
+ }
+ SUBCASE("one without a start velocity still has to run") {
+ rear.min_start_velocity = -1.f;
+ CHECK_FALSE(locomotive->MotorConnectorsCheck());
+ rear.is_active = true;
+ CHECK(locomotive->MotorConnectorsCheck());
+ }
+}
+
+namespace {
+
+bool blowers_run(TMoverParameters const &Mover) {
+ return Mover.MotorBlowers[end::front].is_active && Mover.MotorBlowers[end::rear].is_active;
+}
+
+// the driver's first power position, held until the line contactors close (their delay, the pressure switch)
+bool close_line_contactors(test::driven const &Driven) {
+ Driven.controlling.IncMainCtrl(1);
+ for (int i = 0; i < 30 && false == Driven.controlling.StLinFlag; ++i) {
+ test::drive(Driven, line, 1.0);
+ }
+ return Driven.controlling.StLinFlag;
+}
+
+// the brakes released and the cylinders empty enough for the pressure switch to let the vehicle start
+void release(test::driven const &Driven) {
+ test::release_brakes(Driven.cab);
+ for (int i = 0; i < 90 && (Driven.controlling.BrakePress > 0.1 || Driven.controlling.PipePress < 4.8); ++i) {
+ test::drive(Driven, line, 1.0);
+ }
+}
+
+} // namespace
+
+TEST_CASE("line contactors interlock: with blowers starting with the speed the vehicle starts from a standstill") {
+ // each of the circuits a blower runs off has power before the line contactors close
+ std::string starttype;
+ SUBCASE("blowers off the converter") { starttype = "Converter"; }
+ SUBCASE("blowers off the battery") { starttype = "Battery"; }
+ SUBCASE("blowers switched on by the driver, off the main circuit") { starttype = "Manual"; }
+ CAPTURE(starttype);
+ vehicle eu07{definition::fiz("4e_v1/4e")
+ .set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
+ .set("Cntrl", "MotorBlowersStart", starttype)
+ .set("Engine", "MotorBlowersStartVelocity", 5.0)
+ .set("Engine", "MotorBlowersSustainTime", 10.0),
+ 0.0, "test", 1};
+ auto &mover{eu07.mover()};
+ REQUIRE(mover.LineContactorsInterlock == line_contactors_interlock::motor_blowers);
+ REQUIRE(mover.MotorBlowers[end::front].min_start_velocity == doctest::Approx(5.0));
+ REQUIRE(mover.MotorBlowers[end::rear].sustain_time == doctest::Approx(10.0));
+ auto driven{test::driving(eu07)};
+ REQUIRE(test::start_up(driven, line));
+ release(driven);
+
+ // standing, the blowers don't run; the line contactors close all the same and the motors take current
+ REQUIRE(std::abs(eu07.speed()) < 0.1);
+ REQUIRE_FALSE(blowers_run(mover));
+ CHECK(close_line_contactors(driven));
+ CHECK(std::abs(mover.Im) > 0.5);
+
+ // the blowers come on once the vehicle moves
+ for (int i = 0; i < 6; ++i) {
+ mover.IncMainCtrl(1);
+ test::drive(driven, line, 2.0);
+ }
+ for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
+ test::drive(driven, line, 1.0);
+ }
+ REQUIRE(eu07.speed() >= 10.0);
+ CHECK(blowers_run(mover));
+ CHECK(mover.StLinFlag);
+
+ // a stop longer than the blowers keep running for
+ while (mover.DecMainCtrl(1)) {
+ // down to zero
+ }
+ driven.cab.BrakeLevelSet(driven.cab.Handle->GetPos(bh_FB));
+ for (int i = 0; i < 120 && std::abs(eu07.speed()) > 0.1; ++i) {
+ test::drive(driven, line, 1.0);
+ }
+ REQUIRE(std::abs(eu07.speed()) <= 0.1);
+ test::drive(driven, line, 15.0);
+ REQUIRE_FALSE(blowers_run(mover));
+ REQUIRE_FALSE(mover.StLinFlag);
+
+ // and the vehicle starts again
+ release(driven);
+ CHECK(close_line_contactors(driven));
+ CHECK(std::abs(mover.Im) > 0.5);
+ for (int i = 0; i < 6; ++i) {
+ mover.IncMainCtrl(1);
+ test::drive(driven, line, 2.0);
+ }
+ for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
+ test::drive(driven, line, 1.0);
+ }
+ CHECK(eu07.speed() >= 10.0);
+ CHECK(blowers_run(mover));
+}
+
+TEST_CASE("line contactors interlock: a blower starting with the speed, switched off on the way, opens the contactors") {
+ vehicle eu07{definition::fiz("4e_v1/4e")
+ .set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
+ .set("Cntrl", "MotorBlowersStart", "Manual")
+ .set("Engine", "MotorBlowersStartVelocity", 5.0)
+ .set("Engine", "MotorBlowersSustainTime", 10.0),
+ 0.0, "test", 1};
+ auto &mover{eu07.mover()};
+ auto driven{test::driving(eu07)};
+ REQUIRE(test::start_up(driven, line));
+ release(driven);
+ REQUIRE(close_line_contactors(driven));
+
+ // the switch of the rear blower: off, the contactors open and stay open, standing as well as later
+ REQUIRE(mover.MotorBlowersSwitchOff(true, end::rear));
+ test::drive(driven, line, 2.0);
+ CHECK_FALSE(mover.StLinFlag);
+ CHECK(std::abs(mover.Im) < 0.5);
+ while (mover.DecMainCtrl(1)) {
+ // down to zero
+ }
+ test::drive(driven, line, 2.0);
+ CHECK_FALSE(close_line_contactors(driven));
+
+ // back on, the vehicle starts
+ REQUIRE(mover.MotorBlowersSwitchOff(false, end::rear));
+ while (mover.DecMainCtrl(1)) {
+ // down to zero
+ }
+ test::drive(driven, line, 2.0);
+ CHECK(close_line_contactors(driven));
+ CHECK(std::abs(mover.Im) > 0.5);
+}
+
+TEST_CASE("line contactors interlock: held by the local converter switch only where they wait for that converter") {
+ // what the AI driver looks at to switch the converter of a section back on (TController, the converteron hint)
+ auto interlocked{ready("Converter")};
+ CHECK_FALSE(interlocked->LineContactorsHeldByLocalConverterSwitch());
+ interlocked->ConverterAllowLocal = false;
+ CHECK(interlocked->LineContactorsHeldByLocalConverterSwitch());
+
+ for (auto const *other : {"", "MotorBlowers"}) {
+ CAPTURE(other);
+ auto locomotive{ready(other)};
+ locomotive->ConverterAllowLocal = false;
+ CHECK_FALSE(locomotive->LineContactorsHeldByLocalConverterSwitch());
+ }
+}
+
+TEST_CASE("line contactors interlock: the ET42 section with its fans switched off doesn't start") {
+ test::consist et42;
+ et42.add(definition::fiz("et42_v2/112e-a").set("Cntrl", "LineContactorsInterlock", "Converter"), 1);
+ et42.add(definition::fiz("et42_v2/112e-b").set("Cntrl", "LineContactorsInterlock", "Converter"));
+ auto driven{test::driving(et42)};
+ REQUIRE(test::start_up(driven, line));
+ auto &front{et42[0].mover()};
+ auto &rear{et42[1].mover()};
+ REQUIRE(front.ConverterFlag);
+ REQUIRE(rear.ConverterFlag);
+
+ // the fans of the rear section switched off with its own switch, the 110 V of the front one still reaches it
+ rear.ConverterAllowLocal = false;
+ test::drive(driven, line, 2.0);
+ REQUIRE_FALSE(rear.ConverterFlag);
+ CHECK(rear.Power110vIsAvailable);
+
+ test::release_brakes(driven.cab);
+ for (int i = 0; i < 3 && driven.cab.DirActive <= 0; ++i) {
+ driven.cab.DirectionForward();
+ }
+ test::drive(driven, line, 20.0);
+ driven.controlling.IncMainCtrl(1);
+ // as the AI does, it waits at the first position for the contactors (their delay, the pressure switch)
+ for (int i = 0; i < 90 && false == front.StLinFlag; ++i) {
+ test::drive(driven, line, 1.0);
+ }
+ CHECK(front.StLinFlag);
+ CHECK_FALSE(rear.StLinFlag);
+
+ // the fans back on, the section starts too
+ rear.ConverterAllowLocal = true;
+ test::drive(driven, line, 10.0);
+ REQUIRE(rear.ConverterFlag);
+ CHECK(rear.StLinFlag);
+
+ // and the fans switched off on the way open its line contactors again
+ rear.ConverterAllowLocal = false;
+ test::drive(driven, line, 2.0);
+ CHECK_FALSE(rear.StLinFlag);
+ CHECK(front.StLinFlag);
+}
+
+TEST_CASE("louvres: closed until the main reservoir reaches the pressure that opens them") {
+ vehicle et22{definition::fiz("et22_v3/201e-w")};
+ CHECK(et22->LouvresOpenPressure == doctest::Approx(5.0)); // by default
+ et22->Compressor = 4.9;
+ CHECK(et22->LouvresClosed());
+ et22->Compressor = 5.0;
+ CHECK_FALSE(et22->LouvresClosed());
+
+ vehicle given{definition::fiz("et22_v3/201e-w").set("Cntrl", "LouvresOpenPressure", 4.0)};
+ given->Compressor = 4.5;
+ CHECK_FALSE(given->LouvresClosed());
+ given->Compressor = 3.9;
+ CHECK(given->LouvresClosed());
+}
diff --git a/vehicle/Driver.cpp b/vehicle/Driver.cpp
index a1fc7d30e..eb74344bf 100644
--- a/vehicle/Driver.cpp
+++ b/vehicle/Driver.cpp
@@ -6600,11 +6600,14 @@ TController::determine_consist_state() {
IsAnyConverterPresent = false;
IsAnyConverterEnabled = false;
IsAnyConverterExplicitlyEnabled = false;
+ // whether the line contactors of a vehicle wait for its own converter (LineContactorsInterlock), off with its local switch
+ auto islocalconverterswitchoff { false };
pVehicle->for_each(
coupling::control,
- [this]( TDynamicObject * Vehicle ) {
+ [this, &islocalconverterswitchoff]( TDynamicObject * Vehicle ) {
auto const *vehicle { Vehicle->MoverParameters };
+ islocalconverterswitchoff |= vehicle->LineContactorsHeldByLocalConverterSwitch();
IsAnyConverterOverloadRelayOpen |= vehicle->ConvOvldFlag;
IsAnyMotorOverloadRelayOpen |= vehicle->FuseFlag;
IsAnyGroundRelayOpen |= !vehicle->GroundRelay;
@@ -6675,7 +6678,9 @@ TController::determine_consist_state() {
false == IsAnyConverterOverloadRelayOpen
&& false == IsAnyLineBreakerOpen
&& ( false == IsAnyConverterPresent || true == IsAnyConverterEnabled )
- && ( false == IsAnyCompressorPresent || true == IsAnyCompressorEnabled );
+ && ( false == IsAnyCompressorPresent || true == IsAnyCompressorEnabled )
+ // the ai goes back to preparing the engine and switches that converter on, the human driver may run with it off
+ && ( false == AIControllFlag || false == islocalconverterswitchoff );
}
void
diff --git a/vehicle/Train.cpp b/vehicle/Train.cpp
index ec4bea03d..50659934c 100644
--- a/vehicle/Train.cpp
+++ b/vehicle/Train.cpp
@@ -9332,6 +9332,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaPrzetw.Turn(mvOccupied->Power110vIsAvailable);
btLampkaPrzetwOff.Turn(!mvOccupied->Power110vIsAvailable);
+ btLampkaPrzetwAOff.Turn(!mvControlled->ConverterFlag);
btLampkaNadmPrzetw.Turn(Dynamic()->Mechanik ? Dynamic()->Mechanik->IsAnyConverterOverloadRelayOpen : mvControlled->ConvOvldFlag);
btLampkaOpory.Turn(mvControlled->StLinFlag && mvControlled->ResistorsFlagCheck());
@@ -9479,6 +9480,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaEngineOverheat.Turn(mvControlled->dizel_heat.engine_is_hot);
btLampkaMotorBlowers.Turn(mvControlled->MotorBlowers[end::front].is_active && mvControlled->MotorBlowers[end::rear].is_active);
btLampkaCoolingFans.Turn(mvControlled->RventRot > 1.0);
+ btLampkaLouvresClosed.Turn(mvControlled->LouvresClosed());
btLampkaTempomat.Turn(mvOccupied->SpeedCtrlUnit.IsActive);
btLampkaDistanceCounter.Turn(m_distancecounter >= 0.f);
// universal devices state indicators
@@ -9515,6 +9517,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaNapNastHam.Turn(false);
btLampkaPrzetw.Turn(false);
btLampkaPrzetwOff.Turn(false);
+ btLampkaPrzetwAOff.Turn(false);
btLampkaNadmPrzetw.Turn(false);
btLampkaSprezarka.Turn(false);
btLampkaSprezarkaOff.Turn(false);
@@ -9565,6 +9568,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaMalfunction.Turn(false);
btLampkaMotorBlowers.Turn(false);
btLampkaCoolingFans.Turn(false);
+ btLampkaLouvresClosed.Turn(false);
btLampkaTempomat.Turn(false);
btLampkaDistanceCounter.Turn(false);
// universal devices state indicators
@@ -11615,6 +11619,7 @@ void TTrain::clear_cab_controls()
btLampkaPrzetw.Clear();
btLampkaPrzetwB.Clear();
btLampkaPrzetwBOff.Clear();
+ btLampkaPrzetwAOff.Clear();
btLampkaPrzekRozn.Clear();
btLampkaPrzekRoznPom.Clear();
btLampkaUkrotnienie.Clear();
@@ -11695,6 +11700,7 @@ void TTrain::clear_cab_controls()
btLampkaMalfunctionB.Clear();
btLampkaMotorBlowers.Clear();
btLampkaCoolingFans.Clear();
+ btLampkaLouvresClosed.Clear();
btLampkaTempomat.Clear();
btLampkaDistanceCounter.Clear();
@@ -12048,6 +12054,7 @@ bool TTrain::initialize_button(cParser &Parser, std::string const &Label, int co
{"i-conv_ovld:", btLampkaNadmPrzetw},
{"i-converter:", btLampkaPrzetw},
{"i-converteroff:", btLampkaPrzetwOff},
+ {"i-converteraoff:", btLampkaPrzetwAOff},
{"i-converterb:", btLampkaPrzetwB},
{"i-converterboff:", btLampkaPrzetwBOff},
{"i-diff_relay:", btLampkaPrzekRozn},
@@ -12075,6 +12082,7 @@ bool TTrain::initialize_button(cParser &Parser, std::string const &Label, int co
{"i-vent_trim:", btLampkaWentZaluzje},
{"i-motorblowers:", btLampkaMotorBlowers},
{"i-coolingfans:", btLampkaCoolingFans},
+ {"i-louvresclosed:", btLampkaLouvresClosed},
{"i-tempomat:", btLampkaTempomat},
{"i-distancecounter:", btLampkaDistanceCounter},
{"i-trainheating:", btLampkaOgrzewanieSkladu},
diff --git a/vehicle/Train.h b/vehicle/Train.h
index 82d8377d1..a547eef72 100644
--- a/vehicle/Train.h
+++ b/vehicle/Train.h
@@ -748,6 +748,7 @@ public: // reszta może by?publiczna
TButton btLampkaNadmPrzetw;
TButton btLampkaPrzetw;
TButton btLampkaPrzetwOff;
+ TButton btLampkaPrzetwAOff; // the converter of this very unit off, where the trainset shares its 110 V (ET42 section fans)
TButton btLampkaPrzekRozn; // TODO: implement
TButton btLampkaPrzekRoznPom; // TODO: implement
TButton btLampkaNadmSil;
@@ -854,6 +855,7 @@ public: // reszta może by?publiczna
TButton btLampkaMalfunctionB;
TButton btLampkaMotorBlowers;
TButton btLampkaCoolingFans;
+ TButton btLampkaLouvresClosed; // ET22, the pneumatic louvres of the motor fans not open yet
TButton btLampkaTempomat;