build 170429. partial emulation of pwr system, fixed tracking of pantograph states, other minor bug fixes
This commit is contained in:
39
DynObj.cpp
39
DynObj.cpp
@@ -2463,30 +2463,45 @@ bool TDynamicObject::Update(double dt, double dt1)
|
||||
// if
|
||||
// ((!MoverParameters->PantCompFlag)&&(MoverParameters->CompressedVolume>=2.8))
|
||||
// MoverParameters->PantVolume=MoverParameters->CompressedVolume;
|
||||
if( MoverParameters->PantPress < ( MoverParameters->TrainType == dt_EZT ? 2.5 : 3.5 ) ) {
|
||||
|
||||
if( MoverParameters->PantPress < MoverParameters->EnginePowerSource.CollectorParameters.MinPress ) {
|
||||
// 3.5 wg http://www.transportszynowy.pl/eu06-07pneumat.php
|
||||
// Ra 2013-12: Niebugocław mówi, że w EZT podnoszą się przy 2.5
|
||||
if( true == MoverParameters->PantPressSwitchActive ) {
|
||||
// opuszczenie pantografów przy niskim ciśnieniu
|
||||
/*
|
||||
// NOTE: disabled, the pantographs drop by themseleves when the pantograph tank pressure gets low enough
|
||||
MoverParameters->PantFront( false, ( MoverParameters->TrainType == dt_EZT ? command_range::unit : command_range::local ) );
|
||||
MoverParameters->PantRear( false, ( MoverParameters->TrainType == dt_EZT ? command_range::unit : command_range::local ) );
|
||||
// pressure switch safety measure -- open the line breaker, unless there's alternate source of traction voltage
|
||||
if( MoverParameters->GetTrainsetVoltage() < 0.5 * MoverParameters->EnginePowerSource.MaxVoltage ) {
|
||||
// TODO: check whether line breaker should be open EMU-wide
|
||||
MoverParameters->MainSwitch( false, ( MoverParameters->TrainType == dt_EZT ? command_range::unit : command_range::local ) );
|
||||
*/
|
||||
if( MoverParameters->TrainType != dt_EZT ) {
|
||||
// pressure switch safety measure -- open the line breaker, unless there's alternate source of traction voltage
|
||||
if( MoverParameters->GetTrainsetVoltage() < 0.5 * MoverParameters->EnginePowerSource.MaxVoltage ) {
|
||||
// TODO: check whether line breaker should be open EMU-wide
|
||||
MoverParameters->MainSwitch( false, ( MoverParameters->TrainType == dt_EZT ? command_range::unit : command_range::local ) );
|
||||
}
|
||||
}
|
||||
else {
|
||||
// specialized variant for EMU -- pwr system disables converter and heating,
|
||||
// and prevents their activation until pressure switch is set again
|
||||
MoverParameters->PantPressLockActive = true;
|
||||
// TODO: separate 'heating allowed' from actual heating flag, so we can disable it here without messing up heating toggle
|
||||
MoverParameters->ConverterSwitch( false, command_range::unit );
|
||||
}
|
||||
// mark the pressure switch as spent
|
||||
MoverParameters->PantPressSwitchActive = false;
|
||||
}
|
||||
}
|
||||
else {
|
||||
// prime the pressure switch
|
||||
// TODO: check what decides whether the pressure switch is active, prototypically
|
||||
MoverParameters->PantPressSwitchActive = true;
|
||||
if( MoverParameters->PantPress >= 4.6 ) {
|
||||
// prime the pressure switch
|
||||
MoverParameters->PantPressSwitchActive = true;
|
||||
// turn off the subsystems lock
|
||||
MoverParameters->PantPressLockActive = false;
|
||||
|
||||
if( MoverParameters->PantPress >= 4.8 ) {
|
||||
// Winger - automatyczne wylaczanie malej sprezarki
|
||||
MoverParameters->PantCompFlag = false;
|
||||
if( MoverParameters->PantPress >= 4.8 ) {
|
||||
// Winger - automatyczne wylaczanie malej sprezarki
|
||||
MoverParameters->PantCompFlag = false;
|
||||
}
|
||||
}
|
||||
}
|
||||
/*
|
||||
|
||||