feat: ET22 louvre lamp, lit until the main reservoir opens the louvres (eu07/maszyna#451)

The ET22 cab binds its louvre lamp to i-voltbrake: (voltage on the brake
controller) as a stand-in. The real lamp goes out once the main compressors
have filled the main reservoir to about 5 bar and the pneumatic louvres of
the motor fans open.

- New optional lamp i-louvresclosed:, lit (with low voltage power) while the
  main reservoir pressure is below LouvresOpenPressure.
- New optional Cntrl. key LouvresOpenPressure [bar], 5.0 by default, so the
  .mmd change alone is enough.
- i-vent_trim: (btLampkaWentZaluzje, never driven) is left alone, because
  the WMB10 binds it and would suddenly light up.

SVN data, to change once this is released (old data works as before):
- dynamic/pkp/et22_v3/201eo.mmd.inc, 201eo_160ec.mmd.inc, 201ek.mmd:
  i-voltbrake: lampka_zaluzje -> i-louvresclosed: lampka_zaluzje
- dynamic/pkp/et22-2000_v2/201em.mmd:
  i-voltbrake: zaluzje -> i-louvresclosed: zaluzje

(eu07/maszyna#451)
This commit is contained in:
jerrrrycho
2026-11-07 20:41:06 +01:00
parent f34f912b38
commit d50f51cdff
5 changed files with 28 additions and 0 deletions

View File

@@ -9112,6 +9112,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaEngineOverheat.Turn(mvControlled->dizel_heat.engine_is_hot);
btLampkaMotorBlowers.Turn(mvControlled->MotorBlowers[end::front].is_active && mvControlled->MotorBlowers[end::rear].is_active);
btLampkaCoolingFans.Turn(mvControlled->RventRot > 1.0);
btLampkaLouvresClosed.Turn(mvControlled->LouvresClosed());
btLampkaTempomat.Turn(mvOccupied->SpeedCtrlUnit.IsActive);
btLampkaDistanceCounter.Turn(m_distancecounter >= 0.f);
// universal devices state indicators
@@ -9198,6 +9199,7 @@ bool TTrain::Update(double const Deltatime)
btLampkaMalfunction.Turn(false);
btLampkaMotorBlowers.Turn(false);
btLampkaCoolingFans.Turn(false);
btLampkaLouvresClosed.Turn(false);
btLampkaTempomat.Turn(false);
btLampkaDistanceCounter.Turn(false);
// universal devices state indicators
@@ -11213,6 +11215,7 @@ void TTrain::clear_cab_controls()
btLampkaMalfunctionB.Clear();
btLampkaMotorBlowers.Clear();
btLampkaCoolingFans.Clear();
btLampkaLouvresClosed.Clear();
btLampkaTempomat.Clear();
btLampkaDistanceCounter.Clear();
@@ -11577,6 +11580,7 @@ bool TTrain::initialize_button(cParser &Parser, std::string const &Label, int co
{"i-vent_trim:", btLampkaWentZaluzje},
{"i-motorblowers:", btLampkaMotorBlowers},
{"i-coolingfans:", btLampkaCoolingFans},
{"i-louvresclosed:", btLampkaLouvresClosed},
{"i-tempomat:", btLampkaTempomat},
{"i-distancecounter:", btLampkaDistanceCounter},
{"i-trainheating:", btLampkaOgrzewanieSkladu},