feat: ET22 louvre lamp, lit until the main reservoir opens the louvres (eu07/maszyna#451)
The ET22 cab binds its louvre lamp to i-voltbrake: (voltage on the brake controller) as a stand-in. The real lamp goes out once the main compressors have filled the main reservoir to about 5 bar and the pneumatic louvres of the motor fans open. - New optional lamp i-louvresclosed:, lit (with low voltage power) while the main reservoir pressure is below LouvresOpenPressure. - New optional Cntrl. key LouvresOpenPressure [bar], 5.0 by default, so the .mmd change alone is enough. - i-vent_trim: (btLampkaWentZaluzje, never driven) is left alone, because the WMB10 binds it and would suddenly light up. SVN data, to change once this is released (old data works as before): - dynamic/pkp/et22_v3/201eo.mmd.inc, 201eo_160ec.mmd.inc, 201ek.mmd: i-voltbrake: lampka_zaluzje -> i-louvresclosed: lampka_zaluzje - dynamic/pkp/et22-2000_v2/201em.mmd: i-voltbrake: zaluzje -> i-louvresclosed: zaluzje (eu07/maszyna#451)
This commit is contained in:
@@ -815,6 +815,7 @@ public: // reszta może by?publiczna
|
||||
TButton btLampkaMalfunctionB;
|
||||
TButton btLampkaMotorBlowers;
|
||||
TButton btLampkaCoolingFans;
|
||||
TButton btLampkaLouvresClosed; // ET22, the pneumatic louvres of the motor fans not open yet
|
||||
TButton btLampkaTempomat;
|
||||
TButton btLampkaDistanceCounter;
|
||||
|
||||
|
||||
Reference in New Issue