mirror of
https://github.com/MaSzyna-EU07/maszyna.git
synced 2026-07-21 14:49:19 +02:00
cab textures size limit, generic cab controls return type support, minor bug fixes
This commit is contained in:
@@ -1728,7 +1728,7 @@ void TMoverParameters::HeatingCheck( double const Timestep ) {
|
||||
break;
|
||||
}
|
||||
case TPowerSource::Main: {
|
||||
voltage = ( true == Mains ? PantographVoltage : 0.0 );
|
||||
voltage = ( true == Mains ? std::max( GetAnyTrainsetVoltage(), PantographVoltage ) : 0.0 );
|
||||
break;
|
||||
}
|
||||
default: {
|
||||
@@ -2355,11 +2355,11 @@ bool TMoverParameters::CabActivisation(void)
|
||||
// Q: 20160710
|
||||
// wyłączenie rozrządu
|
||||
// *************************************************************************************************
|
||||
bool TMoverParameters::CabDeactivisation(void)
|
||||
bool TMoverParameters::CabDeactivisation( bool const Force )
|
||||
{
|
||||
bool OK = false;
|
||||
|
||||
OK = (CabNo == ActiveCab); // o ile obsada jest w kabinie ze sterowaniem
|
||||
OK = Force || (CabNo == ActiveCab); // o ile obsada jest w kabinie ze sterowaniem
|
||||
if (OK)
|
||||
{
|
||||
CabNo = 0;
|
||||
@@ -3736,7 +3736,7 @@ void TMoverParameters::CompressorCheck(double dt)
|
||||
if( CompressorPower == 2 ) {
|
||||
CompressorAllow = ConverterAllow;
|
||||
}
|
||||
|
||||
// TODO: clean up compressor CompressorFlag state code, large parts are cloned and an utter mess
|
||||
if (MaxCompressorF - MinCompressorF < 0.0001) {
|
||||
// TODO: investigate purpose of this branch and whether it can be removed as it duplicates later code
|
||||
if( ( true == CompressorAllow )
|
||||
@@ -3802,10 +3802,9 @@ void TMoverParameters::CompressorCheck(double dt)
|
||||
CompressorFlag = (
|
||||
( ( CompressorAllow ) || ( CompressorStart == start_t::automatic ) )
|
||||
&& ( CompressorAllowLocal )
|
||||
&& ( Mains )
|
||||
&& ( ( ConverterFlag )
|
||||
|| ( CompressorPower == 0 )
|
||||
|| ( CompressorPower == 3 ) ) );
|
||||
&& ( CompressorPower == 0 ? Mains :
|
||||
CompressorPower == 3 ? Mains :
|
||||
ConverterFlag ) );
|
||||
|
||||
if( Compressor > MaxCompressorF ) {
|
||||
// wyłącznik ciśnieniowy jest niezależny od sposobu zasilania
|
||||
@@ -3876,12 +3875,11 @@ void TMoverParameters::CompressorCheck(double dt)
|
||||
}
|
||||
else {
|
||||
CompressorFlag = (
|
||||
( ( CompressorAllow ) || ( CompressorStart == start_t::automatic ) )
|
||||
&& ( CompressorAllowLocal )
|
||||
&& ( Mains )
|
||||
&& ( ( ConverterFlag )
|
||||
|| ( CompressorPower == 0 )
|
||||
|| ( CompressorPower == 3 ) ) );
|
||||
( ( CompressorAllow ) || ( CompressorStart == start_t::automatic ) )
|
||||
&& ( CompressorAllowLocal )
|
||||
&& ( CompressorPower == 0 ? Mains :
|
||||
CompressorPower == 3 ? Mains :
|
||||
ConverterFlag ) );
|
||||
}
|
||||
|
||||
// NOTE: crude way to enforce simultaneous activation of compressors in multi-unit setups
|
||||
|
||||