18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-24 21:19:13 +01:00

Merge pull request #272 from MaSzyna-EU07/feat/mains-before-pantographs

Line breaker before the pantographs (`Cntrl.PantRequiresMain`)
This commit is contained in:
maj00r
2026-11-11 22:41:28 +01:00
committed by GitHub
6 changed files with 447 additions and 27 deletions

View File

@@ -2165,6 +2165,11 @@ class TMoverParameters
// config, Engine:JointEngineStart. whether the cab's line breaker / engine start switch works the vehicles in multiple
// too; when it doesn't, the cab has separate switches for them (mainb_*, mainc_*)
bool JointEngineStart{true};
// config, .fiz Cntrl.PantRequiresMain: the line breaker closes without traction voltage and holds without it, and the
// pantographs rise and stay up only while it's closed (EU05, EP05, ČD 181 family); off, the pantographs come first and the line
// breaker needs their voltage. what the main circuit feeds still needs the voltage (MainCircuitPowered()), and without
// it the undervoltage relay opens the line contactors (NoVoltRelay)
bool PantographsRequireMains{false};
bool LineBreakerClosesOnlyAtNoPowerPos{false};
bool ControlPressureSwitch{false}; // activates if the main pipe and/or brake cylinder pressure aren't within operational levels
bool HasControlPressureSwitch{true};
@@ -2230,7 +2235,9 @@ class TMoverParameters
double PantPress = 0.0; /*Cisnienie w zbiornikach pantografow*/
bool PantPressSwitchActive{false}; // state of the pantograph pressure switch. gets primed at defined pressure level in pantograph air system
bool PantPressLockActive{false}; // pwr system state flag. fires when pressure switch activates by pantograph pressure dropping below defined level
bool NoVoltRelay{true}; // switches off if the power level drops below threshold
// switches off if the power level drops below threshold, which opens the line breaker; with PantographsRequireMains
// it opens the line contactors instead, and switches back on only with the master controller at zero or the first position
bool NoVoltRelay{true};
bool OvervoltageRelay{true}; // switches off if the power level goes above threshold
bool s_CAtestebrake = false; // hunter-091012: zmienna dla testu ca
std::array<std::pair<double, double>, 4> PowerCircuits; // 24v, 110v, 3x400v and 3000v power circuits, voltage from local sources and current draw pairs
@@ -2659,6 +2666,11 @@ class TMoverParameters
bool HeatingSwitch(bool const State, range_t const Notify = range_t::consist);
void HeatingSwitch_(bool const State);
double EnginePowerSourceVoltage() const; // returns voltage of defined main engine power source
// whether the main circuit feeds what runs on it (the converter, a compressor, the heating, the motor and resistor
// blowers, the traction motors): the line breaker closed, and where it closes ahead of the pantographs and holds
// without traction voltage (PantographsRequireMains) also the voltage there, at least the one the undervoltage
// trip takes. everywhere else it's the same as Mains
bool MainCircuitPowered() const;
/*-funkcje typowe dla lokomotywy elektrycznej*/
void LowVoltagePowerCheck(double const Deltatime);