fix: line contactors interlocked with speed-started blowers close at a standstill
With LineContactorsInterlock=MotorBlowers the line contactors waited for every motor blower to run. A blower with MotorBlowersStartVelocity starts only with the vehicle moving and the motors drawing current, so standing it never ran, the contactors never closed, no current flowed and the vehicle couldn't start at all; the same after a stop longer than MotorBlowersSustainTime. - For a blower with a start velocity the interlock now asks whether it is switched on and has power (not switched off, switched on where the driver starts it, its power source present), instead of whether it runs. Blowers without a start velocity still have to run. - The power source of a blower (battery: 24 V, converter: 110 V, else the main circuit) is one function, MotorBlowerPowerIsAvailable(), used by MotorBlowersCheck() and the interlock. None of the three needs the line contactors closed: the battery and the converter run before them, and the main circuit is the line breaker they need anyway. (eu07/maszyna#460)
This commit is contained in:
@@ -2403,9 +2403,7 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
|
||||
}
|
||||
blower.is_active =
|
||||
// TODO: bind properly power source when ld is in place
|
||||
(blower.start_type == start_t::battery ? Power24vIsAvailable :
|
||||
blower.start_type == start_t::converter ? Power110vIsAvailable :
|
||||
Mains) // power source
|
||||
MotorBlowerPowerIsAvailable(blower) // power source
|
||||
// breaker condition disabled until it's implemented in the class data
|
||||
// && ( true == blower.breaker )
|
||||
&& false == disable &&
|
||||
@@ -2435,6 +2433,19 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
|
||||
}
|
||||
}
|
||||
|
||||
bool TMoverParameters::MotorBlowerPowerIsAvailable(cooling_fan const &Blower) const
|
||||
{
|
||||
switch (Blower.start_type)
|
||||
{
|
||||
case start_t::battery:
|
||||
return Power24vIsAvailable;
|
||||
case start_t::converter:
|
||||
return Power110vIsAvailable;
|
||||
default:
|
||||
return Mains;
|
||||
}
|
||||
}
|
||||
|
||||
void TMoverParameters::PantographsCheck(double const /*Timestep*/)
|
||||
{
|
||||
using enum start_t;
|
||||
@@ -7503,7 +7514,16 @@ bool TMoverParameters::LineContactorsInterlockReleased() const
|
||||
// the converter of this very vehicle, not the 110 V of the trainset: a section with its fans off doesn't start
|
||||
return ConverterFlag;
|
||||
case line_contactors_interlock::motor_blowers:
|
||||
return std::ranges::all_of(MotorBlowers, [](auto const &Blower) { return Blower.is_active; });
|
||||
return std::ranges::all_of(MotorBlowers, [this](auto const &Blower) {
|
||||
if (Blower.min_start_velocity < 0)
|
||||
{
|
||||
return Blower.is_active;
|
||||
}
|
||||
// a blower which starts with the speed and the motor current (MotorBlowersStartVelocity) can't run before
|
||||
// the contactors close, nor after a stop longer than it keeps running for: it's enough that it's
|
||||
// switched on and has power, so it starts once the vehicle moves
|
||||
return MotorBlowerPowerIsAvailable(Blower) && false == Blower.is_disabled && (Blower.start_type == start_t::manual ? Blower.is_enabled : true);
|
||||
});
|
||||