18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-20 08:04:57 +01:00
Commit Graph

2 Commits

Author SHA1 Message Date
jerrrrycho
226eaabb7b fix: behind a line breaker closed ahead of the pantographs the main circuit still needs the voltage
Review of #272. The closed line breaker used to mean there's traction
voltage, the undervoltage trip opening it without one. With
PantRequiresMain=Yes it closes on the battery and holds without voltage,
so everything that took Mains for "the main circuit is live" ran with the
pantographs down, lowered for a section, or under a dead catenary.

- MainCircuitPowered(): the line breaker closed, and on a vehicle with
  PantRequiresMain and current collectors also the voltage at least MinV
  (what the undervoltage trip takes). For every other vehicle it is Mains.
  It feeds the converter (and through it the 110 V and a compressor on
  it), a compressor on the main circuit, the heating from the main
  circuit, the motor blowers, the blowers of the starting resistors, the
  current of the series motors and the induction motor drive.
- The undervoltage relay of such a vehicle opens the line contactors, as
  the line breaker opening did elsewhere: the camshaft goes back to zero
  and the motors get no current, also not the generator current a closed
  circuit without voltage gave. The relay picks up again with the voltage
  back and the master controller at zero or the first position, so the
  start begins anew instead of the camshaft running back up to the
  position left on the controller.

Vehicles without the key are unchanged: the golden traces recorded before
the change compare exactly.
2026-11-11 21:54:20 +01:00
jerrrrycho
5a20f86fd0 feat: line breaker before the pantographs, Cntrl.PantRequiresMain (#68)
New optional .fiz key Cntrl.PantRequiresMain (default No, every existing
vehicle unchanged). With Yes, as on Czech-built locomotives:
- the line breaker closes on the low voltage circuits, without traction
  voltage, and the undervoltage trip doesn't open it (overvoltage and the
  other trips still do);
- a pantograph valve opens and stays open only while the vehicle's line
  breaker is closed, so opening it drops the pantographs.

The AI (TController::PrepareEngine) closes the line breaker before raising
the pantographs for such a vehicle; the line breaker steps moved into
TController::close_line_breaker(). test::start_up() follows the same order.

Game data: to use it, PantRequiresMain=Yes goes on the Cntrl. line of
dynamic/pkp/ep05_v2/ep05.fiz, ep05v1.fiz and dynamic/cd/181_v2/181_cz1.fiz,
18x_pl.fiz (left for later, not part of this change). (#68)
2026-11-07 19:18:37 +01:00