Author SHA1 Message Date
jerrrrycho
5f46aca43a fix: a latching line breaker lever goes off with the breaker knocked out (#277)
The EP05's single two-state line breaker lever stayed on once the converter
overload relay knocked the breaker out: every press of the toggle tried to
close the open breaker, which the tripped relay refused. A press now puts
a lever left on over an open breaker off first.

(eu07/maszyna#394)