The ET22 cab binds its louvre lamp to i-voltbrake: (voltage on the brake
controller) as a stand-in. The real lamp goes out once the main compressors
have filled the main reservoir to about 5 bar and the pneumatic louvres of
the motor fans open.
- New optional lamp i-louvresclosed:, lit (with low voltage power) while the
main reservoir pressure is below LouvresOpenPressure.
- New optional Cntrl. key LouvresOpenPressure [bar], 5.0 by default, so the
.mmd change alone is enough.
- i-vent_trim: (btLampkaWentZaluzje, never driven) is left alone, because
the WMB10 binds it and would suddenly light up.
SVN data, to change once this is released (old data works as before):
- dynamic/pkp/et22_v3/201eo.mmd.inc, 201eo_160ec.mmd.inc, 201ek.mmd:
i-voltbrake: lampka_zaluzje -> i-louvresclosed: lampka_zaluzje
- dynamic/pkp/et22-2000_v2/201em.mmd:
i-voltbrake: zaluzje -> i-louvresclosed: zaluzje
(eu07/maszyna#451)
On the ET42 the fans of each section run off that section's converter: the
section fan switch of the cab is bound to converterlocal_sw. The line
contactors of a section with its fans switched off must not close.
- New optional Cntrl. key LineContactorsInterlock=Converter|MotorBlowers.
MotorConnectorsCheck() then also needs the vehicle's own converter
(ConverterFlag, not the trainset's shared 110 V), or all its motor
blowers, running. It is checked per vehicle, so only that section stays
off, and switching the fans off on the way opens its contactors. Without
the key nothing changes.
- New optional lamp i-converteraoff:, lit while the converter of the
vehicle with the cab is off. i-converteroff: follows the shared 110 V, so
with one ET42 section's fans off it stayed dark. i-converterboff: already
covers the other section.
SVN data, to change once this is released (old data works as before):
- dynamic/pkp/et42_v2/112e-a.fiz, 112e-b.fiz: LineContactorsInterlock=Converter
in the Cntrl. line.
- dynamic/pkp/et42_v2/112e-a.mmd.inc, 112e-b.mmd.inc:
i-converter: nadm_przetw -> i-converteraoff: nadm_przetw,
i-converterb: nadm_przetw_b -> i-converterboff: nadm_przetw_b,
i-compressor: sprezarka -> i-compressoroff: sprezarka,
i-compressorb: sprezarka_b -> i-compressorboff: sprezarka_b
(the compressor "off" lamps already light with the compressor switched off
or stopped by its pressure governor).
(eu07/maszyna#460)