main_off_bt declared with "type: toggle" in the cab's .mmd is now the
line breaker's hold coil lever of the ET22 and EP09: it stays where it is
put. Off, it opens the line breaker and keeps it from closing (also
cancelling a closing armed by a held main_on_bt); back on, it only feeds
the coil again. The single keyboard key puts the lever back on before
closing, and a line breaker closed by the AI or through the control
cable puts the lever back on to match.
TGauge now remembers whether type: was given, since every control
defaults to toggle. Without type: on main_off_bt (all vehicles today)
nothing changes.
Data (SVN, not part of this commit): add "type: toggle" to main_off_bt:
in dynamic/pkp/et22_v3/*.mmd and dynamic/pkp/ep09_v1, ep09_v2/*.mmd.
Older exes ignore it.