#include "stdafx.h" #include "doctest.h" #include "scenario.h" #include "vehicle/fieldshunting.h" // the field shunting of the diesel-electric locomotives, set by the driver or by the shunting relays, and the switch // of the SU45 and the SP45 that lets the relays shunt the field ("załączenie bocznikowania", eu07/maszyna#167) using test::definition; using test::scenario; using namespace test::channels; TEST_CASE("field shunting: who shunts the field of a diesel-electric, by AutoRelay, FieldShuntSwitch and the switch") { using enum fieldshunting::control; struct setting { int type; // AutoRelay: 0 No, 1 Yes, 2 Optional bool fieldshuntswitch; // FieldShuntSwitch bool flag; // the switch, AutoRelayFlag fieldshunting::control expected; }; for (auto const &[type, fieldshuntswitch, flag, expected] : {setting{0, false, false, manual}, setting{1, false, true, automatic}, // AutoRelay=Optional alone, as before: off, the driver shunts by hand setting{2, false, true, automatic}, setting{2, false, false, manual}, // with FieldShuntSwitch=Yes the switch of the field shunting: off, nobody setting{2, true, true, automatic}, setting{2, true, false, off}, // FieldShuntSwitch=Yes without the switch (AutoRelay=Yes or No) changes nothing setting{1, true, true, automatic}, setting{0, true, false, manual}, // AutoRelaySwitch from a coupled vehicle turns the flag of every one off, as before setting{1, false, false, manual}, setting{1, true, false, manual}}) { CAPTURE(type); CAPTURE(fieldshuntswitch); CAPTURE(flag); CHECK(fieldshunting::diesel_electric(type, fieldshuntswitch, flag) == expected); CHECK(fieldshunting::has_switch(type, fieldshuntswitch) == (type == 2 && fieldshuntswitch)); } } TEST_CASE("field shunting: the SU45 with its switch, off at full power and switched on and off on the move") { // the SU45 (RelayType 45) given the switch (AutoRelay=Optional, FieldShuntSwitch=Yes) its cab has, with a coach: // off, the field stays full and the second controller can't shunt it; on, the relays shunt it as they do with // AutoRelay=Yes; off again, the shunting drops scenario scenario{"traction/field shunting switch/su45", motion() + traction()}; scenario.train().add(definition::fiz("su45_v2/301d").set("Cntrl", "AutoRelay", "Optional").set("Cntrl", "FieldShuntSwitch", "Yes"), 1); scenario.add("bdhpumn_v3/bdhpumn"); REQUIRE(scenario.start_up()); auto &su45{scenario.driver().controlling}; REQUIRE(su45.AutoRelayType == 2); REQUIRE(su45.FieldShuntSwitch); // the driver switches it on as the AI does, getting the locomotive ready CHECK(su45.AutoRelayFlag); scenario.act("field shunting off"); CHECK(su45.AutoRelaySwitch(false)); scenario.get_going(); scenario.full_power(120.0); CHECK(su45.IsMainCtrlMaxPowerPos()); CHECK(su45.StLinFlag); CHECK(su45.ScndCtrlPos == 0); CHECK_FALSE(su45.IncScndCtrl(1)); scenario.wait(1.0); CHECK(su45.ScndCtrlPos == 0); // over 50 km/h, where the relays of the SU45 let the third stage in CHECK(su45.Vel > 50.0); scenario.act("field shunting on"); CHECK(su45.AutoRelaySwitch(true)); scenario.wait(30.0); CHECK(su45.ScndCtrlPos == su45.ScndCtrlPosNo); scenario.act("field shunting off on the move"); CHECK(su45.AutoRelaySwitch(false)); scenario.wait(1.0); CHECK(su45.ScndCtrlPos == 0); scenario.check(); } TEST_CASE("field shunting: a diesel-electric with AutoRelay=Optional alone shunts by hand with the switch off, as before") { // the SU45 with AutoRelay=Optional but no FieldShuntSwitch: the switch is the old one, off hands the shunting to the // second controller, and the start-up (as the AI) leaves it off scenario scenario{"traction/field shunting switch/su45 optional alone", motion() + traction()}; scenario.train().add(definition::fiz("su45_v2/301d").set("Cntrl", "AutoRelay", "Optional"), 1); scenario.add("bdhpumn_v3/bdhpumn"); REQUIRE(scenario.start_up()); auto &su45{scenario.driver().controlling}; REQUIRE(su45.AutoRelayType == 2); REQUIRE_FALSE(su45.FieldShuntSwitch); CHECK_FALSE(su45.AutoRelayFlag); scenario.get_going(); scenario.full_power(120.0); CHECK(su45.IsMainCtrlMaxPowerPos()); CHECK(su45.StLinFlag); // over 50 km/h: the relays don't shunt, the driver does CHECK(su45.Vel > 50.0); CHECK(su45.ScndCtrlPos == 0); scenario.act("field shunting by hand"); CHECK(su45.IncScndCtrl(1)); scenario.wait(1.0); CHECK(su45.ScndCtrlPos == 1); scenario.check(); }