On the electric locomotives the lamp of the open line contactors tells the start can be made, so it goes out with the start cut off by the pressure switch. The diesel-electric SU45 and SU46 (the only diesel-electrics with the lamp) use it just to show the contactors are open, but it went out the same way: with too low a pressure in the main pipe the contactors were open and the lamp out. Once the pressure came back with the master controller past the first position, the contactors stayed open, as they should, and the lamp lit up on a power position, which looked like the lamp working the other way round. On the diesel-electrics TMoverParameters::LineContactorsLampLit() now follows the contactors alone; the electric locomotives and the other main circuit lamps are unchanged. Tests: tests/unit/test_line_contactors.cpp, on a locomotive made after the SU46.
131 lines
4.6 KiB
C++
131 lines
4.6 KiB
C++
#include "stdafx.h"
|
|
#include "doctest.h"
|
|
#include "vehicle.h"
|
|
|
|
// the lamp of the open line contactors (eu07/maszyna#470): lit, it tells the start can be made, so it should go out
|
|
// where the start is cut off, by the pressure switch at 2 bar in the brake cylinders, not at 1 bar already
|
|
|
|
namespace {
|
|
|
|
test::vehicle locomotive(bool const Pressureswitch) {
|
|
test::vehicle vehicle{test::definition::load("wagon").set("Engine", "PressureSwitch", Pressureswitch)};
|
|
vehicle->StLinFlag = false; // the line contactors open
|
|
vehicle->PipePress = 5.0;
|
|
return vehicle;
|
|
}
|
|
|
|
} // namespace
|
|
|
|
TEST_CASE("line contactors: with a pressure switch the lamp goes out with the start cut off") {
|
|
auto vehicle{locomotive(true)};
|
|
REQUIRE(vehicle->HasControlPressureSwitch);
|
|
|
|
vehicle->BrakePress = 1.5; // braked, the start can still be made
|
|
vehicle->MotorConnectorsCheck(); // updates the pressure switch
|
|
REQUIRE_FALSE(vehicle->ControlPressureSwitch);
|
|
CHECK(vehicle->LineContactorsLampLit());
|
|
|
|
vehicle->BrakePress = 2.5; // the pressure switch cuts the start off
|
|
vehicle->MotorConnectorsCheck();
|
|
REQUIRE(vehicle->ControlPressureSwitch);
|
|
CHECK_FALSE(vehicle->LineContactorsLampLit());
|
|
}
|
|
|
|
TEST_CASE("line contactors: without a pressure switch the lamp goes out with the brakes applied, as before") {
|
|
auto vehicle{locomotive(false)};
|
|
vehicle->BrakePress = 0.5;
|
|
vehicle->MotorConnectorsCheck();
|
|
CHECK(vehicle->LineContactorsLampLit());
|
|
vehicle->BrakePress = 1.5;
|
|
vehicle->MotorConnectorsCheck();
|
|
CHECK_FALSE(vehicle->LineContactorsLampLit());
|
|
}
|
|
|
|
TEST_CASE("line contactors: closed contactors put the lamp out") {
|
|
auto vehicle{locomotive(true)};
|
|
vehicle->StLinFlag = true;
|
|
CHECK_FALSE(vehicle->LineContactorsLampLit());
|
|
}
|
|
|
|
TEST_CASE("line contactors: the ground relay and overload lamps follow the same rule") {
|
|
// all the lamps of the main circuit go out together, with the pressure switch where it's fitted
|
|
auto vehicle{locomotive(true)};
|
|
vehicle->BrakePress = 1.5;
|
|
vehicle->MotorConnectorsCheck();
|
|
CHECK(vehicle->MainCircuitLampsEnabled());
|
|
vehicle->BrakePress = 2.5;
|
|
vehicle->MotorConnectorsCheck();
|
|
CHECK_FALSE(vehicle->MainCircuitLampsEnabled());
|
|
}
|
|
|
|
// on the diesel-electric SU45 and SU46 (eu07/maszyna#263) the lamp tells just the line contactors are open: lit with the
|
|
// master controller at 0 and with the start cut off by too low a pressure in the main pipe, out on the power positions
|
|
|
|
namespace {
|
|
|
|
// the diesel-electric locomotive with its engine running and the brakes released, the master controller at 0
|
|
test::vehicle diesel_electric() {
|
|
test::vehicle vehicle{test::definition::load("diesel_electric")};
|
|
vehicle->CabOccupied = 1;
|
|
vehicle->CabActivisation();
|
|
vehicle->BatterySwitch(true);
|
|
vehicle->OilPumpSwitch(true);
|
|
vehicle->FuelPumpSwitch(true);
|
|
vehicle.run(20.0); // the oil pressure builds up
|
|
vehicle.hold_brake_pipe(5.0); // bar
|
|
vehicle->MainSwitch(true);
|
|
vehicle.run(30.0);
|
|
vehicle->DirectionForward();
|
|
vehicle.run(60.0); // the brakes release
|
|
return vehicle;
|
|
}
|
|
|
|
} // namespace
|
|
|
|
TEST_CASE("line contactors: on a diesel-electric the lamp is lit at 0 and goes out on a power position") {
|
|
auto vehicle{diesel_electric()};
|
|
REQUIRE(vehicle->EngineType == TEngineType::DieselElectric);
|
|
REQUIRE(vehicle->Mains);
|
|
REQUIRE_FALSE(vehicle->ControlPressureSwitch);
|
|
CHECK_FALSE(vehicle->StLinFlag);
|
|
CHECK(vehicle->LineContactorsLampLit());
|
|
|
|
vehicle->IncMainCtrl(1);
|
|
vehicle.run(3.0);
|
|
CHECK(vehicle->StLinFlag);
|
|
CHECK_FALSE(vehicle->LineContactorsLampLit());
|
|
|
|
vehicle->DecMainCtrl(1);
|
|
vehicle.run(3.0);
|
|
CHECK_FALSE(vehicle->StLinFlag);
|
|
CHECK(vehicle->LineContactorsLampLit());
|
|
}
|
|
|
|
TEST_CASE("line contactors: on a diesel-electric the lamp lights with the contactors opened by too low a main pipe pressure") {
|
|
auto vehicle{diesel_electric()};
|
|
vehicle->IncMainCtrl(1);
|
|
vehicle.run(1.0);
|
|
vehicle->IncMainCtrl(1);
|
|
vehicle.run(2.0);
|
|
REQUIRE(vehicle->StLinFlag);
|
|
|
|
vehicle.hold_brake_pipe(2.5); // bar, below the 3.6 bar of the pressure switch
|
|
vehicle.run(10.0);
|
|
REQUIRE(vehicle->ControlPressureSwitch);
|
|
CHECK_FALSE(vehicle->StLinFlag);
|
|
CHECK(vehicle->LineContactorsLampLit()); // it went out here
|
|
CHECK_FALSE(vehicle->MainCircuitLampsEnabled()); // the ground relay and overload lamps still go out with the start cut off
|
|
|
|
// the pressure back, the contactors stay open on the second position and the lamp stays lit, as it should;
|
|
// they close again only on the first one
|
|
vehicle.hold_brake_pipe(5.0);
|
|
vehicle.run(60.0);
|
|
REQUIRE_FALSE(vehicle->ControlPressureSwitch);
|
|
CHECK_FALSE(vehicle->StLinFlag);
|
|
CHECK(vehicle->LineContactorsLampLit());
|
|
vehicle->DecMainCtrl(1);
|
|
vehicle.run(3.0);
|
|
CHECK(vehicle->StLinFlag);
|
|
CHECK_FALSE(vehicle->LineContactorsLampLit());
|
|
}
|