jerrrrycho 226eaabb7b fix: behind a line breaker closed ahead of the pantographs the main circuit still needs the voltage
Review of #272. The closed line breaker used to mean there's traction
voltage, the undervoltage trip opening it without one. With
PantRequiresMain=Yes it closes on the battery and holds without voltage,
so everything that took Mains for "the main circuit is live" ran with the
pantographs down, lowered for a section, or under a dead catenary.

- MainCircuitPowered(): the line breaker closed, and on a vehicle with
  PantRequiresMain and current collectors also the voltage at least MinV
  (what the undervoltage trip takes). For every other vehicle it is Mains.
  It feeds the converter (and through it the 110 V and a compressor on
  it), a compressor on the main circuit, the heating from the main
  circuit, the motor blowers, the blowers of the starting resistors, the
  current of the series motors and the induction motor drive.
- The undervoltage relay of such a vehicle opens the line contactors, as
  the line breaker opening did elsewhere: the camshaft goes back to zero
  and the motors get no current, also not the generator current a closed
  circuit without voltage gave. The relay picks up again with the voltage
  back and the master controller at zero or the first position, so the
  start begins anew instead of the camshaft running back up to the
  position left on the controller.

Vehicles without the key are unchanged: the golden traces recorded before
the change compare exactly.