18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-14 17:58:36 +01:00
Files
maszyna/tests
jerrrrycho 5bc4e7cd2e feat: lock field shunting at zero and on resistive positions
New optional Cntrl. key ScndCtrlResistiveLock=Yes: IncScndCtrl() refuses
to step the shunt controller up while the master controller is at its
no-power position or on a resistive RList position (R >= 0.01), as the
interlock of the ET21, ET22 and EP09 does. Decreasing the shunt stays
allowed so it can't get stuck. The AI doesn't choose field shunting
while the lock applies. Without the key nothing changes.

Game data: the key is to be added to the Cntrl. line of the ET21
(et21_v2), ET22 (et22_v3, et22-2000_v2) and EP09 (ep09_v1, ep09_v2)
.fiz files that define it; until then they behave as before.

(eu07/maszyna#402)
2026-11-07 21:01:54 +01:00
..