// the line breaker (main switch, WS) controls of the cab
|
|
namespace linebreaker {
|
|
|
|
enum class toggle : int {
|
|
none, // the press does nothing
|
|
close, // the control goes to its on position, and the line breaker closes if it can
|
|
open // the control goes to its off position, and the line breaker opens
|
|
};
|
|
|
|
// what a press of the line breaker toggle does. Breakerstate is the state the cab keeps of the line
|
|
// breaker (0: open, 1: closed, 2: freshly closed). Latchinglever is a single two-state switch which
|
|
// stays where it was put, Leveron that it stands in its on position. such a lever doesn't follow the
|
|
// line breaker: knocked out (by the converter overload relay, say) the breaker opens with the lever
|
|
// left on, and the lever has to go off before it can be put on again (eu07/maszyna#394)
|
|
toggle pressed(int Breakerstate, bool Latchinglever, bool Leveron);
|
|
|
|