The EP05's single two-state line breaker lever stayed on once the converter overload relay knocked the breaker out: every press of the toggle tried to close the open breaker, which the tripped relay refused. A press now puts a lever left on over an open breaker off first. (eu07/maszyna#394)
27 lines
626 B
C++
27 lines
626 B
C++
/*
|
|
This Source Code Form is subject to the
|
|
terms of the Mozilla Public License, v.
|
|
2.0. If a copy of the MPL was not
|
|
distributed with this file, You can
|
|
obtain one at
|
|
http://mozilla.org/MPL/2.0/.
|
|
*/
|
|
|
|
#include "stdafx.h"
|
|
#include "vehicle/linebreaker.h"
|
|
|
|
namespace linebreaker {
|
|
|
|
toggle pressed(int const Breakerstate, bool const Latchinglever, bool const Leveron) {
|
|
if (Breakerstate == 1) {
|
|
return toggle::open;
|
|
}
|
|
if (Breakerstate != 0) {
|
|
return toggle::none;
|
|
}
|
|
// the line breaker is open; a lever left on goes off first
|
|
return Latchinglever && Leveron ? toggle::open : toggle::close;
|
|
}
|
|
|
|
} // namespace linebreaker
|