18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-19 12:16:02 +01:00
Files
maszyna/vehicle/holdcoillever.h
jerrrrycho d7c66fa7bc feat: bistable hold coil lever of the line breaker (eu07/maszyna#364)
main_off_bt declared with "type: toggle" in the cab's .mmd is now the
line breaker's hold coil lever of the ET22 and EP09: it stays where it is
put. Off, it opens the line breaker and keeps it from closing (also
cancelling a closing armed by a held main_on_bt); back on, it only feeds
the coil again. The single keyboard key puts the lever back on before
closing, and a line breaker closed by the AI or through the control
cable puts the lever back on to match.

TGauge now remembers whether type: was given, since every control
defaults to toggle. Without type: on main_off_bt (all vehicles today)
nothing changes.

Data (SVN, not part of this commit): add "type: toggle" to main_off_bt:
in dynamic/pkp/et22_v3/*.mmd and dynamic/pkp/ep09_v1, ep09_v2/*.mmd.
Older exes ignore it.
2026-11-07 18:10:59 +01:00

35 lines
1.3 KiB
C++

/*
This Source Code Form is subject to the
terms of the Mozilla Public License, v.
2.0. If a copy of the MPL was not
distributed with this file, You can
obtain one at
http://mozilla.org/MPL/2.0/.
*/
#pragma once
// the lever of the line breaker's hold coil (eu07/maszyna#364), as on the ET22 and the EP09: the cab's main_off_bt
// control declared with "type: toggle" stays in the position it's put in. Position 0 keeps the hold coil fed, so the
// line breaker can be closed; position 1 cuts the coil off, which opens the line breaker and keeps it from closing
// until the lever is put back. Without the declared type main_off_bt stays the push button it always was, which
// opens the line breaker and springs back.
namespace hold_coil_lever {
// whether the main_off_bt control is the bistable lever, from the type its definition declares, if it declares one
inline bool is_bistable(bool const Typedeclared, bool const Toggletype) {
return Typedeclared && Toggletype;
}
// whether the lever in the given position cuts off the hold coil
inline bool cuts_off(float const Position) {
return Position > 0.5f;
}
// the position the lever goes to when it's operated: the other one
inline float operated(float const Position) {
return cuts_off(Position) ? 0.f : 1.f;
}
} // namespace hold_coil_lever