mirror of
https://github.com/MaSzyna-EU07/maszyna.git
synced 2026-11-20 17:25:00 +01:00
With LineContactorsInterlock=MotorBlowers the line contactors waited for every motor blower to run. A blower with MotorBlowersStartVelocity starts only with the vehicle moving and the motors drawing current, so standing it never ran, the contactors never closed, no current flowed and the vehicle couldn't start at all; the same after a stop longer than MotorBlowersSustainTime. - For a blower with a start velocity the interlock now asks whether it is switched on and has power (not switched off, switched on where the driver starts it, its power source present), instead of whether it runs. Blowers without a start velocity still have to run. - The power source of a blower (battery: 24 V, converter: 110 V, else the main circuit) is one function, MotorBlowerPowerIsAvailable(), used by MotorBlowersCheck() and the interlock. None of the three needs the line contactors closed: the battery and the converter run before them, and the main circuit is the line breaker they need anyway. (eu07/maszyna#460)