With LineContactorsInterlock=MotorBlowers the line contactors waited for every motor blower to run. A blower with MotorBlowersStartVelocity starts only with the vehicle moving and the motors drawing current, so standing it never ran, the contactors never closed, no current flowed and the vehicle couldn't start at all; the same after a stop longer than MotorBlowersSustainTime. - For a blower with a start velocity the interlock now asks whether it is switched on and has power (not switched off, switched on where the driver starts it, its power source present), instead of whether it runs. Blowers without a start velocity still have to run. - The power source of a blower (battery: 24 V, converter: 110 V, else the main circuit) is one function, MotorBlowerPowerIsAvailable(), used by MotorBlowersCheck() and the interlock. None of the three needs the line contactors closed: the battery and the converter run before them, and the main circuit is the line breaker they need anyway. (eu07/maszyna#460)
301 lines
11 KiB
C++
301 lines
11 KiB
C++
#include "stdafx.h"
|
|
#include "doctest.h"
|
|
#include "consist.h"
|
|
#include "drive.h"
|
|
#include "vehicle.h"
|
|
|
|
#include "McZapkie/hamulce.h"
|
|
|
|
// the line contactors interlocked with the fans of the traction motors (eu07/maszyna#460): on the ET42 the fans of a
|
|
// section run off its own converter, and with them switched off the line contactors of that section don't close.
|
|
// the louvres of the fans of the ET22 open with the air of the main reservoir (eu07/maszyna#451)
|
|
|
|
using test::definition;
|
|
using test::vehicle;
|
|
|
|
namespace {
|
|
|
|
// a vehicle whose line contactors could close, but for the interlock
|
|
vehicle ready(std::string_view const Interlock) {
|
|
auto loaded{definition::load("wagon")};
|
|
if (false == Interlock.empty()) {
|
|
loaded.set("Cntrl", "LineContactorsInterlock", std::string{Interlock});
|
|
}
|
|
vehicle locomotive{loaded};
|
|
locomotive->Mains = true;
|
|
locomotive->DirActive = 1;
|
|
locomotive->PipePress = 5.0;
|
|
locomotive->BrakePress = 0.0;
|
|
return locomotive;
|
|
}
|
|
|
|
test::track const line{0.15, 0.0, test::catenary_3kv};
|
|
|
|
} // namespace
|
|
|
|
TEST_CASE("line contactors interlock: read from the Cntrl. section, none by default") {
|
|
CHECK(ready("")->LineContactorsInterlock == line_contactors_interlock::none);
|
|
CHECK(ready("Converter")->LineContactorsInterlock == line_contactors_interlock::converter);
|
|
CHECK(ready("MotorBlowers")->LineContactorsInterlock == line_contactors_interlock::motor_blowers);
|
|
CHECK(ready("Something")->LineContactorsInterlock == line_contactors_interlock::none);
|
|
}
|
|
|
|
TEST_CASE("line contactors interlock: without one the converter and the blowers don't matter, as before") {
|
|
auto locomotive{ready("")};
|
|
locomotive->ConverterFlag = false;
|
|
for (auto &blower : locomotive->MotorBlowers) {
|
|
blower.is_active = false;
|
|
}
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
}
|
|
|
|
TEST_CASE("line contactors interlock: on the converter, they close only with the vehicle's own converter running") {
|
|
auto locomotive{ready("Converter")};
|
|
locomotive->ConverterFlag = false;
|
|
locomotive->Power110vIsAvailable = true; // the 110 V from the other section doesn't run this one's fans
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
locomotive->ConverterFlag = true;
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
locomotive->Mains = false; // the other conditions still hold
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
}
|
|
|
|
TEST_CASE("line contactors interlock: on the motor blowers, they close only with all of them running") {
|
|
auto locomotive{ready("MotorBlowers")};
|
|
locomotive->MotorBlowers[end::front].is_active = true;
|
|
locomotive->MotorBlowers[end::rear].is_active = false;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
locomotive->MotorBlowers[end::rear].is_active = true;
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
}
|
|
|
|
// a blower with MotorBlowersStartVelocity starts with the speed and the motor current, so it can't be running before
|
|
// the line contactors close, nor after a stop longer than it keeps running for (MotorBlowersSustainTime): the interlock
|
|
// takes it switched on and powered instead, or the vehicle would never take power
|
|
|
|
TEST_CASE("line contactors interlock: a blower starting with the speed needs to be switched on and powered, not running") {
|
|
auto locomotive{ready("MotorBlowers")};
|
|
for (auto &blower : locomotive->MotorBlowers) {
|
|
blower.min_start_velocity = 5.f;
|
|
blower.is_enabled = true; // switched on by the driver
|
|
blower.is_active = false; // the vehicle stands
|
|
}
|
|
REQUIRE(locomotive->MotorBlowers[end::front].start_type == start_t::manual);
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
|
|
auto &rear{locomotive->MotorBlowers[end::rear]};
|
|
SUBCASE("switched off, it holds the contactors open") {
|
|
rear.is_disabled = true;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
}
|
|
SUBCASE("not switched on, it holds the contactors open") {
|
|
rear.is_enabled = false;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
}
|
|
SUBCASE("off the converter, it needs the 110 V") {
|
|
rear.start_type = start_t::converter;
|
|
rear.is_enabled = false; // nothing for the driver to switch on
|
|
locomotive->Power110vIsAvailable = false;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
locomotive->Power110vIsAvailable = true;
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
}
|
|
SUBCASE("off the battery, it needs the 24 V") {
|
|
rear.start_type = start_t::battery;
|
|
locomotive->Power24vIsAvailable = false;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
locomotive->Power24vIsAvailable = true;
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
}
|
|
SUBCASE("one without a start velocity still has to run") {
|
|
rear.min_start_velocity = -1.f;
|
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
|
rear.is_active = true;
|
|
CHECK(locomotive->MotorConnectorsCheck());
|
|
}
|
|
}
|
|
|
|
namespace {
|
|
|
|
bool blowers_run(TMoverParameters const &Mover) {
|
|
return Mover.MotorBlowers[end::front].is_active && Mover.MotorBlowers[end::rear].is_active;
|
|
}
|
|
|
|
// the driver's first power position, held until the line contactors close (their delay, the pressure switch)
|
|
bool close_line_contactors(test::driven const &Driven) {
|
|
Driven.controlling.IncMainCtrl(1);
|
|
for (int i = 0; i < 30 && false == Driven.controlling.StLinFlag; ++i) {
|
|
test::drive(Driven, line, 1.0);
|
|
}
|
|
return Driven.controlling.StLinFlag;
|
|
}
|
|
|
|
// the brakes released and the cylinders empty enough for the pressure switch to let the vehicle start
|
|
void release(test::driven const &Driven) {
|
|
test::release_brakes(Driven.cab);
|
|
for (int i = 0; i < 90 && (Driven.controlling.BrakePress > 0.1 || Driven.controlling.PipePress < 4.8); ++i) {
|
|
test::drive(Driven, line, 1.0);
|
|
}
|
|
}
|
|
|
|
} // namespace
|
|
|
|
TEST_CASE("line contactors interlock: with blowers starting with the speed the vehicle starts from a standstill") {
|
|
// each of the circuits a blower runs off has power before the line contactors close
|
|
std::string starttype;
|
|
SUBCASE("blowers off the converter") { starttype = "Converter"; }
|
|
SUBCASE("blowers off the battery") { starttype = "Battery"; }
|
|
SUBCASE("blowers switched on by the driver, off the main circuit") { starttype = "Manual"; }
|
|
CAPTURE(starttype);
|
|
vehicle eu07{definition::fiz("4e_v1/4e")
|
|
.set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
|
|
.set("Cntrl", "MotorBlowersStart", starttype)
|
|
.set("Engine", "MotorBlowersStartVelocity", 5.0)
|
|
.set("Engine", "MotorBlowersSustainTime", 10.0),
|
|
0.0, "test", 1};
|
|
auto &mover{eu07.mover()};
|
|
REQUIRE(mover.LineContactorsInterlock == line_contactors_interlock::motor_blowers);
|
|
REQUIRE(mover.MotorBlowers[end::front].min_start_velocity == doctest::Approx(5.0));
|
|
REQUIRE(mover.MotorBlowers[end::rear].sustain_time == doctest::Approx(10.0));
|
|
auto driven{test::driving(eu07)};
|
|
REQUIRE(test::start_up(driven, line));
|
|
release(driven);
|
|
|
|
// standing, the blowers don't run; the line contactors close all the same and the motors take current
|
|
REQUIRE(std::abs(eu07.speed()) < 0.1);
|
|
REQUIRE_FALSE(blowers_run(mover));
|
|
CHECK(close_line_contactors(driven));
|
|
CHECK(std::abs(mover.Im) > 0.5);
|
|
|
|
// the blowers come on once the vehicle moves
|
|
for (int i = 0; i < 6; ++i) {
|
|
mover.IncMainCtrl(1);
|
|
test::drive(driven, line, 2.0);
|
|
}
|
|
for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
|
|
test::drive(driven, line, 1.0);
|
|
}
|
|
REQUIRE(eu07.speed() >= 10.0);
|
|
CHECK(blowers_run(mover));
|
|
CHECK(mover.StLinFlag);
|
|
|
|
// a stop longer than the blowers keep running for
|
|
while (mover.DecMainCtrl(1)) {
|
|
// down to zero
|
|
}
|
|
driven.cab.BrakeLevelSet(driven.cab.Handle->GetPos(bh_FB));
|
|
for (int i = 0; i < 120 && std::abs(eu07.speed()) > 0.1; ++i) {
|
|
test::drive(driven, line, 1.0);
|
|
}
|
|
REQUIRE(std::abs(eu07.speed()) <= 0.1);
|
|
test::drive(driven, line, 15.0);
|
|
REQUIRE_FALSE(blowers_run(mover));
|
|
REQUIRE_FALSE(mover.StLinFlag);
|
|
|
|
// and the vehicle starts again
|
|
release(driven);
|
|
CHECK(close_line_contactors(driven));
|
|
CHECK(std::abs(mover.Im) > 0.5);
|
|
for (int i = 0; i < 6; ++i) {
|
|
mover.IncMainCtrl(1);
|
|
test::drive(driven, line, 2.0);
|
|
}
|
|
for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
|
|
test::drive(driven, line, 1.0);
|
|
}
|
|
CHECK(eu07.speed() >= 10.0);
|
|
CHECK(blowers_run(mover));
|
|
}
|
|
|
|
TEST_CASE("line contactors interlock: a blower starting with the speed, switched off on the way, opens the contactors") {
|
|
vehicle eu07{definition::fiz("4e_v1/4e")
|
|
.set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
|
|
.set("Cntrl", "MotorBlowersStart", "Manual")
|
|
.set("Engine", "MotorBlowersStartVelocity", 5.0)
|
|
.set("Engine", "MotorBlowersSustainTime", 10.0),
|
|
0.0, "test", 1};
|
|
auto &mover{eu07.mover()};
|
|
auto driven{test::driving(eu07)};
|
|
REQUIRE(test::start_up(driven, line));
|
|
release(driven);
|
|
REQUIRE(close_line_contactors(driven));
|
|
|
|
// the switch of the rear blower: off, the contactors open and stay open, standing as well as later
|
|
REQUIRE(mover.MotorBlowersSwitchOff(true, end::rear));
|
|
test::drive(driven, line, 2.0);
|
|
CHECK_FALSE(mover.StLinFlag);
|
|
CHECK(std::abs(mover.Im) < 0.5);
|
|
while (mover.DecMainCtrl(1)) {
|
|
// down to zero
|
|
}
|
|
test::drive(driven, line, 2.0);
|
|
CHECK_FALSE(close_line_contactors(driven));
|
|
|
|
// back on, the vehicle starts
|
|
REQUIRE(mover.MotorBlowersSwitchOff(false, end::rear));
|
|
while (mover.DecMainCtrl(1)) {
|
|
// down to zero
|
|
}
|
|
test::drive(driven, line, 2.0);
|
|
CHECK(close_line_contactors(driven));
|
|
CHECK(std::abs(mover.Im) > 0.5);
|
|
}
|
|
|
|
TEST_CASE("line contactors interlock: the ET42 section with its fans switched off doesn't start") {
|
|
test::consist et42;
|
|
et42.add(definition::fiz("et42_v2/112e-a").set("Cntrl", "LineContactorsInterlock", "Converter"), 1);
|
|
et42.add(definition::fiz("et42_v2/112e-b").set("Cntrl", "LineContactorsInterlock", "Converter"));
|
|
auto driven{test::driving(et42)};
|
|
REQUIRE(test::start_up(driven, line));
|
|
auto &front{et42[0].mover()};
|
|
auto &rear{et42[1].mover()};
|
|
REQUIRE(front.ConverterFlag);
|
|
REQUIRE(rear.ConverterFlag);
|
|
|
|
// the fans of the rear section switched off with its own switch, the 110 V of the front one still reaches it
|
|
rear.ConverterAllowLocal = false;
|
|
test::drive(driven, line, 2.0);
|
|
REQUIRE_FALSE(rear.ConverterFlag);
|
|
CHECK(rear.Power110vIsAvailable);
|
|
|
|
test::release_brakes(driven.cab);
|
|
for (int i = 0; i < 3 && driven.cab.DirActive <= 0; ++i) {
|
|
driven.cab.DirectionForward();
|
|
}
|
|
test::drive(driven, line, 20.0);
|
|
driven.controlling.IncMainCtrl(1);
|
|
// as the AI does, it waits at the first position for the contactors (their delay, the pressure switch)
|
|
for (int i = 0; i < 90 && false == front.StLinFlag; ++i) {
|
|
test::drive(driven, line, 1.0);
|
|
}
|
|
CHECK(front.StLinFlag);
|
|
CHECK_FALSE(rear.StLinFlag);
|
|
|
|
// the fans back on, the section starts too
|
|
rear.ConverterAllowLocal = true;
|
|
test::drive(driven, line, 10.0);
|
|
REQUIRE(rear.ConverterFlag);
|
|
CHECK(rear.StLinFlag);
|
|
|
|
// and the fans switched off on the way open its line contactors again
|
|
rear.ConverterAllowLocal = false;
|
|
test::drive(driven, line, 2.0);
|
|
CHECK_FALSE(rear.StLinFlag);
|
|
CHECK(front.StLinFlag);
|
|
}
|
|
|
|
TEST_CASE("louvres: closed until the main reservoir reaches the pressure that opens them") {
|
|
vehicle et22{definition::fiz("et22_v3/201e-w")};
|
|
CHECK(et22->LouvresOpenPressure == doctest::Approx(5.0)); // by default
|
|
et22->Compressor = 4.9;
|
|
CHECK(et22->LouvresClosed());
|
|
et22->Compressor = 5.0;
|
|
CHECK_FALSE(et22->LouvresClosed());
|
|
|
|
vehicle given{definition::fiz("et22_v3/201e-w").set("Cntrl", "LouvresOpenPressure", 4.0)};
|
|
given->Compressor = 4.5;
|
|
CHECK_FALSE(given->LouvresClosed());
|
|
given->Compressor = 3.9;
|
|
CHECK(given->LouvresClosed());
|
|
}
|