fix: line contactors interlocked with speed-started blowers close at a standstill
With LineContactorsInterlock=MotorBlowers the line contactors waited for every motor blower to run. A blower with MotorBlowersStartVelocity starts only with the vehicle moving and the motors drawing current, so standing it never ran, the contactors never closed, no current flowed and the vehicle couldn't start at all; the same after a stop longer than MotorBlowersSustainTime. - For a blower with a start velocity the interlock now asks whether it is switched on and has power (not switched off, switched on where the driver starts it, its power source present), instead of whether it runs. Blowers without a start velocity still have to run. - The power source of a blower (battery: 24 V, converter: 110 V, else the main circuit) is one function, MotorBlowerPowerIsAvailable(), used by MotorBlowersCheck() and the interlock. None of the three needs the line contactors closed: the battery and the converter run before them, and the main circuit is the line breaker they need anyway. (eu07/maszyna#460)
This commit is contained in:
@@ -2688,6 +2688,8 @@ class TMoverParameters
|
|||||||
void FuelPumpCheck(double const Timestep);
|
void FuelPumpCheck(double const Timestep);
|
||||||
void OilPumpCheck(double const Timestep);
|
void OilPumpCheck(double const Timestep);
|
||||||
void MotorBlowersCheck(double const Timestep);
|
void MotorBlowersCheck(double const Timestep);
|
||||||
|
// whether the circuit a traction motor blower runs off has power: the battery, the converter or the main circuit, by its start type
|
||||||
|
bool MotorBlowerPowerIsAvailable(cooling_fan const &Blower) const;
|
||||||
void PantographsCheck(double const Timestep);
|
void PantographsCheck(double const Timestep);
|
||||||
void LightsCheck(double const Timestep);
|
void LightsCheck(double const Timestep);
|
||||||
bool FuseOn(range_t const Notify = range_t::consist); // bezpiecznik nadamiary
|
bool FuseOn(range_t const Notify = range_t::consist); // bezpiecznik nadamiary
|
||||||
|
|||||||
@@ -2403,9 +2403,7 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
|
|||||||
}
|
}
|
||||||
blower.is_active =
|
blower.is_active =
|
||||||
// TODO: bind properly power source when ld is in place
|
// TODO: bind properly power source when ld is in place
|
||||||
(blower.start_type == start_t::battery ? Power24vIsAvailable :
|
MotorBlowerPowerIsAvailable(blower) // power source
|
||||||
blower.start_type == start_t::converter ? Power110vIsAvailable :
|
|
||||||
Mains) // power source
|
|
||||||
// breaker condition disabled until it's implemented in the class data
|
// breaker condition disabled until it's implemented in the class data
|
||||||
// && ( true == blower.breaker )
|
// && ( true == blower.breaker )
|
||||||
&& false == disable &&
|
&& false == disable &&
|
||||||
@@ -2435,6 +2433,19 @@ void TMoverParameters::MotorBlowersCheck(double const Timestep)
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
bool TMoverParameters::MotorBlowerPowerIsAvailable(cooling_fan const &Blower) const
|
||||||
|
{
|
||||||
|
switch (Blower.start_type)
|
||||||
|
{
|
||||||
|
case start_t::battery:
|
||||||
|
return Power24vIsAvailable;
|
||||||
|
case start_t::converter:
|
||||||
|
return Power110vIsAvailable;
|
||||||
|
default:
|
||||||
|
return Mains;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
void TMoverParameters::PantographsCheck(double const /*Timestep*/)
|
void TMoverParameters::PantographsCheck(double const /*Timestep*/)
|
||||||
{
|
{
|
||||||
using enum start_t;
|
using enum start_t;
|
||||||
@@ -7503,7 +7514,16 @@ bool TMoverParameters::LineContactorsInterlockReleased() const
|
|||||||
// the converter of this very vehicle, not the 110 V of the trainset: a section with its fans off doesn't start
|
// the converter of this very vehicle, not the 110 V of the trainset: a section with its fans off doesn't start
|
||||||
return ConverterFlag;
|
return ConverterFlag;
|
||||||
case line_contactors_interlock::motor_blowers:
|
case line_contactors_interlock::motor_blowers:
|
||||||
return std::ranges::all_of(MotorBlowers, [](auto const &Blower) { return Blower.is_active; });
|
return std::ranges::all_of(MotorBlowers, [this](auto const &Blower) {
|
||||||
|
if (Blower.min_start_velocity < 0)
|
||||||
|
{
|
||||||
|
return Blower.is_active;
|
||||||
|
}
|
||||||
|
// a blower which starts with the speed and the motor current (MotorBlowersStartVelocity) can't run before
|
||||||
|
// the contactors close, nor after a stop longer than it keeps running for: it's enough that it's
|
||||||
|
// switched on and has power, so it starts once the vehicle moves
|
||||||
|
return MotorBlowerPowerIsAvailable(Blower) && false == Blower.is_disabled && (Blower.start_type == start_t::manual ? Blower.is_enabled : true);
|
||||||
|
});
|
||||||
default:
|
default:
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -4,6 +4,8 @@
|
|||||||
#include "drive.h"
|
#include "drive.h"
|
||||||
#include "vehicle.h"
|
#include "vehicle.h"
|
||||||
|
|
||||||
|
#include "McZapkie/hamulce.h"
|
||||||
|
|
||||||
// the line contactors interlocked with the fans of the traction motors (eu07/maszyna#460): on the ET42 the fans of a
|
// the line contactors interlocked with the fans of the traction motors (eu07/maszyna#460): on the ET42 the fans of a
|
||||||
// section run off its own converter, and with them switched off the line contactors of that section don't close.
|
// section run off its own converter, and with them switched off the line contactors of that section don't close.
|
||||||
// the louvres of the fans of the ET22 open with the air of the main reservoir (eu07/maszyna#451)
|
// the louvres of the fans of the ET22 open with the air of the main reservoir (eu07/maszyna#451)
|
||||||
@@ -67,6 +69,178 @@ TEST_CASE("line contactors interlock: on the motor blowers, they close only with
|
|||||||
CHECK(locomotive->MotorConnectorsCheck());
|
CHECK(locomotive->MotorConnectorsCheck());
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// a blower with MotorBlowersStartVelocity starts with the speed and the motor current, so it can't be running before
|
||||||
|
// the line contactors close, nor after a stop longer than it keeps running for (MotorBlowersSustainTime): the interlock
|
||||||
|
// takes it switched on and powered instead, or the vehicle would never take power
|
||||||
|
|
||||||
|
TEST_CASE("line contactors interlock: a blower starting with the speed needs to be switched on and powered, not running") {
|
||||||
|
auto locomotive{ready("MotorBlowers")};
|
||||||
|
for (auto &blower : locomotive->MotorBlowers) {
|
||||||
|
blower.min_start_velocity = 5.f;
|
||||||
|
blower.is_enabled = true; // switched on by the driver
|
||||||
|
blower.is_active = false; // the vehicle stands
|
||||||
|
}
|
||||||
|
REQUIRE(locomotive->MotorBlowers[end::front].start_type == start_t::manual);
|
||||||
|
CHECK(locomotive->MotorConnectorsCheck());
|
||||||
|
|
||||||
|
auto &rear{locomotive->MotorBlowers[end::rear]};
|
||||||
|
SUBCASE("switched off, it holds the contactors open") {
|
||||||
|
rear.is_disabled = true;
|
||||||
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
||||||
|
}
|
||||||
|
SUBCASE("not switched on, it holds the contactors open") {
|
||||||
|
rear.is_enabled = false;
|
||||||
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
||||||
|
}
|
||||||
|
SUBCASE("off the converter, it needs the 110 V") {
|
||||||
|
rear.start_type = start_t::converter;
|
||||||
|
rear.is_enabled = false; // nothing for the driver to switch on
|
||||||
|
locomotive->Power110vIsAvailable = false;
|
||||||
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
||||||
|
locomotive->Power110vIsAvailable = true;
|
||||||
|
CHECK(locomotive->MotorConnectorsCheck());
|
||||||
|
}
|
||||||
|
SUBCASE("off the battery, it needs the 24 V") {
|
||||||
|
rear.start_type = start_t::battery;
|
||||||
|
locomotive->Power24vIsAvailable = false;
|
||||||
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
||||||
|
locomotive->Power24vIsAvailable = true;
|
||||||
|
CHECK(locomotive->MotorConnectorsCheck());
|
||||||
|
}
|
||||||
|
SUBCASE("one without a start velocity still has to run") {
|
||||||
|
rear.min_start_velocity = -1.f;
|
||||||
|
CHECK_FALSE(locomotive->MotorConnectorsCheck());
|
||||||
|
rear.is_active = true;
|
||||||
|
CHECK(locomotive->MotorConnectorsCheck());
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
namespace {
|
||||||
|
|
||||||
|
bool blowers_run(TMoverParameters const &Mover) {
|
||||||
|
return Mover.MotorBlowers[end::front].is_active && Mover.MotorBlowers[end::rear].is_active;
|
||||||
|
}
|
||||||
|
|
||||||
|
// the driver's first power position, held until the line contactors close (their delay, the pressure switch)
|
||||||
|
bool close_line_contactors(test::driven const &Driven) {
|
||||||
|
Driven.controlling.IncMainCtrl(1);
|
||||||
|
for (int i = 0; i < 30 && false == Driven.controlling.StLinFlag; ++i) {
|
||||||
|
test::drive(Driven, line, 1.0);
|
||||||
|
}
|
||||||
|
return Driven.controlling.StLinFlag;
|
||||||
|
}
|
||||||
|
|
||||||
|
// the brakes released and the cylinders empty enough for the pressure switch to let the vehicle start
|
||||||
|
void release(test::driven const &Driven) {
|
||||||
|
test::release_brakes(Driven.cab);
|
||||||
|
for (int i = 0; i < 90 && (Driven.controlling.BrakePress > 0.1 || Driven.controlling.PipePress < 4.8); ++i) {
|
||||||
|
test::drive(Driven, line, 1.0);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
} // namespace
|
||||||
|
|
||||||
|
TEST_CASE("line contactors interlock: with blowers starting with the speed the vehicle starts from a standstill") {
|
||||||
|
// each of the circuits a blower runs off has power before the line contactors close
|
||||||
|
std::string starttype;
|
||||||
|
SUBCASE("blowers off the converter") { starttype = "Converter"; }
|
||||||
|
SUBCASE("blowers off the battery") { starttype = "Battery"; }
|
||||||
|
SUBCASE("blowers switched on by the driver, off the main circuit") { starttype = "Manual"; }
|
||||||
|
CAPTURE(starttype);
|
||||||
|
vehicle eu07{definition::fiz("4e_v1/4e")
|
||||||
|
.set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
|
||||||
|
.set("Cntrl", "MotorBlowersStart", starttype)
|
||||||
|
.set("Engine", "MotorBlowersStartVelocity", 5.0)
|
||||||
|
.set("Engine", "MotorBlowersSustainTime", 10.0),
|
||||||
|
0.0, "test", 1};
|
||||||
|
auto &mover{eu07.mover()};
|
||||||
|
REQUIRE(mover.LineContactorsInterlock == line_contactors_interlock::motor_blowers);
|
||||||
|
REQUIRE(mover.MotorBlowers[end::front].min_start_velocity == doctest::Approx(5.0));
|
||||||
|
REQUIRE(mover.MotorBlowers[end::rear].sustain_time == doctest::Approx(10.0));
|
||||||
|
auto driven{test::driving(eu07)};
|
||||||
|
REQUIRE(test::start_up(driven, line));
|
||||||
|
release(driven);
|
||||||
|
|
||||||
|
// standing, the blowers don't run; the line contactors close all the same and the motors take current
|
||||||
|
REQUIRE(std::abs(eu07.speed()) < 0.1);
|
||||||
|
REQUIRE_FALSE(blowers_run(mover));
|
||||||
|
CHECK(close_line_contactors(driven));
|
||||||
|
CHECK(std::abs(mover.Im) > 0.5);
|
||||||
|
|
||||||
|
// the blowers come on once the vehicle moves
|
||||||
|
for (int i = 0; i < 6; ++i) {
|
||||||
|
mover.IncMainCtrl(1);
|
||||||
|
test::drive(driven, line, 2.0);
|
||||||
|
}
|
||||||
|
for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
|
||||||
|
test::drive(driven, line, 1.0);
|
||||||
|
}
|
||||||
|
REQUIRE(eu07.speed() >= 10.0);
|
||||||
|
CHECK(blowers_run(mover));
|
||||||
|
CHECK(mover.StLinFlag);
|
||||||
|
|
||||||
|
// a stop longer than the blowers keep running for
|
||||||
|
while (mover.DecMainCtrl(1)) {
|
||||||
|
// down to zero
|
||||||
|
}
|
||||||
|
driven.cab.BrakeLevelSet(driven.cab.Handle->GetPos(bh_FB));
|
||||||
|
for (int i = 0; i < 120 && std::abs(eu07.speed()) > 0.1; ++i) {
|
||||||
|
test::drive(driven, line, 1.0);
|
||||||
|
}
|
||||||
|
REQUIRE(std::abs(eu07.speed()) <= 0.1);
|
||||||
|
test::drive(driven, line, 15.0);
|
||||||
|
REQUIRE_FALSE(blowers_run(mover));
|
||||||
|
REQUIRE_FALSE(mover.StLinFlag);
|
||||||
|
|
||||||
|
// and the vehicle starts again
|
||||||
|
release(driven);
|
||||||
|
CHECK(close_line_contactors(driven));
|
||||||
|
CHECK(std::abs(mover.Im) > 0.5);
|
||||||
|
for (int i = 0; i < 6; ++i) {
|
||||||
|
mover.IncMainCtrl(1);
|
||||||
|
test::drive(driven, line, 2.0);
|
||||||
|
}
|
||||||
|
for (int i = 0; i < 60 && eu07.speed() < 10.0; ++i) {
|
||||||
|
test::drive(driven, line, 1.0);
|
||||||
|
}
|
||||||
|
CHECK(eu07.speed() >= 10.0);
|
||||||
|
CHECK(blowers_run(mover));
|
||||||
|
}
|
||||||
|
|
||||||
|
TEST_CASE("line contactors interlock: a blower starting with the speed, switched off on the way, opens the contactors") {
|
||||||
|
vehicle eu07{definition::fiz("4e_v1/4e")
|
||||||
|
.set("Cntrl", "LineContactorsInterlock", "MotorBlowers")
|
||||||
|
.set("Cntrl", "MotorBlowersStart", "Manual")
|
||||||
|
.set("Engine", "MotorBlowersStartVelocity", 5.0)
|
||||||
|
.set("Engine", "MotorBlowersSustainTime", 10.0),
|
||||||
|
0.0, "test", 1};
|
||||||
|
auto &mover{eu07.mover()};
|
||||||
|
auto driven{test::driving(eu07)};
|
||||||
|
REQUIRE(test::start_up(driven, line));
|
||||||
|
release(driven);
|
||||||
|
REQUIRE(close_line_contactors(driven));
|
||||||
|
|
||||||
|
// the switch of the rear blower: off, the contactors open and stay open, standing as well as later
|
||||||
|
REQUIRE(mover.MotorBlowersSwitchOff(true, end::rear));
|
||||||
|
test::drive(driven, line, 2.0);
|
||||||
|
CHECK_FALSE(mover.StLinFlag);
|
||||||
|
CHECK(std::abs(mover.Im) < 0.5);
|
||||||
|
while (mover.DecMainCtrl(1)) {
|
||||||
|
// down to zero
|
||||||
|
}
|
||||||
|
test::drive(driven, line, 2.0);
|
||||||
|
CHECK_FALSE(close_line_contactors(driven));
|
||||||
|
|
||||||
|
// back on, the vehicle starts
|
||||||
|
REQUIRE(mover.MotorBlowersSwitchOff(false, end::rear));
|
||||||
|
while (mover.DecMainCtrl(1)) {
|
||||||
|
// down to zero
|
||||||
|
}
|
||||||
|
test::drive(driven, line, 2.0);
|
||||||
|
CHECK(close_line_contactors(driven));
|
||||||
|
CHECK(std::abs(mover.Im) > 0.5);
|
||||||
|
}
|
||||||
|
|
||||||
TEST_CASE("line contactors interlock: the ET42 section with its fans switched off doesn't start") {
|
TEST_CASE("line contactors interlock: the ET42 section with its fans switched off doesn't start") {
|
||||||
test::consist et42;
|
test::consist et42;
|
||||||
et42.add(definition::fiz("et42_v2/112e-a").set("Cntrl", "LineContactorsInterlock", "Converter"), 1);
|
et42.add(definition::fiz("et42_v2/112e-a").set("Cntrl", "LineContactorsInterlock", "Converter"), 1);
|
||||||
|
|||||||
Reference in New Issue
Block a user