18
0
mirror of https://github.com/MaSzyna-EU07/maszyna.git synced 2026-11-27 21:45:16 +01:00
Files
maszyna/vehicle/DynObj.cpp
jerrrrycho 8a185ee980 fix: exchange the main reservoir pipe air between vehicles after all of them stepped, in sub-steps
The main reservoir hoses (ctrain_scndpneumatic) exchanged the air explicitly inside each vehicle's step at the
physics step of 0.01 s, as the brake hoses did before eu07/maszyna#387. One step through the hose (0.38 of
area, whatever the vehicles) moves about 1.5 times the air which evens out the pipes on its ends (EN57 cars
8.3 l per bar against 5.5 l, SM40 8.6 against 5.7, passenger cars 9.3 against 6.3), and the vehicles with a
main reservoir of their own feed the pipe from it in the same step. Where a vehicle has both, and hoses on both
ends, the pipe can't settle: with all the main reservoirs held at 7.0 bar, the middle cars of a three unit EN57
kept jumping 0.8 bar to and fro between the steps for good (6.6/7.4), three SM40s in multiple traction the
same, a two unit Impuls 1.7 bar. Freely evening out, the reservoirs of a three unit EN57 took 13.9 s at 0.01 s
against 7.6 s at 0.001 s. A locomotive with passenger cars, whose pipe only it feeds, was stable already.

The main reservoir pipe now goes through the brake pipe's mechanism: UpdateScndPipePressure() leaves the hose
exchange to UpdatePipeCouplers() (GetScndDVc(), ScndPipeCouplersSubsteps(), 2 sub-steps for these vehicles),
which vehicle_table::update_brake_pipes() calls after every vehicle stepped. The two pipes share the code and
take their sub-steps apart, so the brake pipe's exchange is as it was. With it the EN57 pipes stand at 7.000,
and its reservoirs even out in 7.0 s against 7.5 s at 0.001 s.
2026-11-16 18:03:03 +01:00

406 KiB