mirror of
https://github.com/MaSzyna-EU07/maszyna.git
synced 2026-11-28 01:07:07 +01:00
* fix: a switch of the field shunting of the diesel-electrics, and its cab control (GE#167)
The SU45 and SP45 shunt the field of their motors by relays (RelayType 45),
which the driver lets work with a toggle switch on the desk ("załączenie
bocznikowania"). The game had no such switch: AutoRelay=Yes shunts always,
and AutoRelay=Optional on a diesel-electric meant manual shunting with the
switch off. No cab control showed the switch either, so the lever of the
SU45's cab (zalaczbocznikow) had nothing to follow.
- AutoRelay=Optional on a diesel-electric: switched off, no shunting at all
(fieldshunting::diesel_electric() in the core library, used by
IncScndCtrl() and the shunting relays in TractionForce()). No
diesel-electric of the game data uses AutoRelay=Optional; AutoRelay=Yes
and No don't change.
- A new cab control, autorelay_sw:, showing AutoRelayFlag and toggling it
with notchingrelaytoggle on a click.
- The AI switches it on as it gets a diesel-electric ready.
Needs the game data (SVN) to take effect, after the release:
- dynamic/pkp/su45_v2/301d.fiz, sp45_v1/301db.fiz, 301db-152.fiz:
AutoRelay=Yes -> AutoRelay=Optional
- dynamic/pkp/su45_v2/301d.mmd, sp45_v1/301db.mmd, 301db-152.mmd,
301db_factory.mmd: add
autorelay_sw: { zalaczbocznikow rot 0.11 0 0.1 soundinc: 20786_203E_switch_converter_2_on.wav sounddec: 20786_203E_switch_converter_2_of.wav }
Without them the vehicles behave as before.
* refactor(mover): the field shunting switch without Sonar issues
The control is declared in the if that uses it, the relays' branch tests
AutoRelayFlag as before (the same condition as the automatic control, and
no deeper nesting on a changed line), using enum in diesel_electric(),
and the test no longer shadows the name control. No change in behaviour.
* fix(ai): the AI turns the field shunting switch on while running too
It did so only in PrepareEngine(), which isn't called again while the
engine runs, so a running SU45 handed to the AI with the switch off
stayed on full field.
* fix(mover): AutoRelay=Optional keeps its meaning, the field shunting switch is FieldShuntSwitch=Yes
AutoRelay=Optional means again what it did for every diesel-electric: with the
switch off, the driver shunts the field by hand with the second controller. The
switch that leaves the field full when off, as on the SU45 and SP45, is opted
into with a new Cntrl. key, FieldShuntSwitch=Yes, next to AutoRelay=Optional.
A key rather than a new AutoRelay value: the parser reads an AutoRelay value it
doesn't know as No, so an older exe would take the relays away from the SU45,
while it skips an unknown key. The value stays Optional, which every check of
the switch looks for.
The AI switches it on only in a vehicle with the key; one with AutoRelay=Optional
alone is left as before. The SVN data then needs "AutoRelay=Optional
FieldShuntSwitch=Yes" on line 9 of su45_v2/301d.fiz, sp45_v1/301db.fiz and
sp45_v1/301db-152.fiz, after this is released; without it nothing changes.
100 lines
4.4 KiB
C++
100 lines
4.4 KiB
C++
#include "stdafx.h"
|
|
#include "doctest.h"
|
|
#include "scenario.h"
|
|
|
|
#include "vehicle/fieldshunting.h"
|
|
|
|
// the field shunting of the diesel-electric locomotives, set by the driver or by the shunting relays, and the switch
|
|
// of the SU45 and the SP45 that lets the relays shunt the field ("załączenie bocznikowania", eu07/maszyna#167)
|
|
|
|
using test::definition;
|
|
using test::scenario;
|
|
using namespace test::channels;
|
|
|
|
TEST_CASE("field shunting: who shunts the field of a diesel-electric, by AutoRelay, FieldShuntSwitch and the switch") {
|
|
using enum fieldshunting::control;
|
|
struct setting {
|
|
int type; // AutoRelay: 0 No, 1 Yes, 2 Optional
|
|
bool fieldshuntswitch; // FieldShuntSwitch
|
|
bool flag; // the switch, AutoRelayFlag
|
|
fieldshunting::control expected;
|
|
};
|
|
for (auto const &[type, fieldshuntswitch, flag, expected] :
|
|
{setting{0, false, false, manual}, setting{1, false, true, automatic},
|
|
// AutoRelay=Optional alone, as before: off, the driver shunts by hand
|
|
setting{2, false, true, automatic}, setting{2, false, false, manual},
|
|
// with FieldShuntSwitch=Yes the switch of the field shunting: off, nobody
|
|
setting{2, true, true, automatic}, setting{2, true, false, off},
|
|
// FieldShuntSwitch=Yes without the switch (AutoRelay=Yes or No) changes nothing
|
|
setting{1, true, true, automatic}, setting{0, true, false, manual},
|
|
// AutoRelaySwitch from a coupled vehicle turns the flag of every one off, as before
|
|
setting{1, false, false, manual}, setting{1, true, false, manual}}) {
|
|
CAPTURE(type);
|
|
CAPTURE(fieldshuntswitch);
|
|
CAPTURE(flag);
|
|
CHECK(fieldshunting::diesel_electric(type, fieldshuntswitch, flag) == expected);
|
|
CHECK(fieldshunting::has_switch(type, fieldshuntswitch) == (type == 2 && fieldshuntswitch));
|
|
}
|
|
}
|
|
|
|
TEST_CASE("field shunting: the SU45 with its switch, off at full power and switched on and off on the move") {
|
|
// the SU45 (RelayType 45) given the switch (AutoRelay=Optional, FieldShuntSwitch=Yes) its cab has, with a coach:
|
|
// off, the field stays full and the second controller can't shunt it; on, the relays shunt it as they do with
|
|
// AutoRelay=Yes; off again, the shunting drops
|
|
scenario scenario{"traction/field shunting switch/su45", motion() + traction()};
|
|
scenario.train().add(definition::fiz("su45_v2/301d").set("Cntrl", "AutoRelay", "Optional").set("Cntrl", "FieldShuntSwitch", "Yes"), 1);
|
|
scenario.add("bdhpumn_v3/bdhpumn");
|
|
REQUIRE(scenario.start_up());
|
|
auto &su45{scenario.driver().controlling};
|
|
REQUIRE(su45.AutoRelayType == 2);
|
|
REQUIRE(su45.FieldShuntSwitch);
|
|
// the driver switches it on as the AI does, getting the locomotive ready
|
|
CHECK(su45.AutoRelayFlag);
|
|
scenario.act("field shunting off");
|
|
CHECK(su45.AutoRelaySwitch(false));
|
|
scenario.get_going();
|
|
scenario.full_power(120.0);
|
|
CHECK(su45.IsMainCtrlMaxPowerPos());
|
|
CHECK(su45.StLinFlag);
|
|
CHECK(su45.ScndCtrlPos == 0);
|
|
CHECK_FALSE(su45.IncScndCtrl(1));
|
|
scenario.wait(1.0);
|
|
CHECK(su45.ScndCtrlPos == 0);
|
|
// over 50 km/h, where the relays of the SU45 let the third stage in
|
|
CHECK(su45.Vel > 50.0);
|
|
scenario.act("field shunting on");
|
|
CHECK(su45.AutoRelaySwitch(true));
|
|
scenario.wait(30.0);
|
|
CHECK(su45.ScndCtrlPos == su45.ScndCtrlPosNo);
|
|
scenario.act("field shunting off on the move");
|
|
CHECK(su45.AutoRelaySwitch(false));
|
|
scenario.wait(1.0);
|
|
CHECK(su45.ScndCtrlPos == 0);
|
|
scenario.check();
|
|
}
|
|
|
|
TEST_CASE("field shunting: a diesel-electric with AutoRelay=Optional alone shunts by hand with the switch off, as before") {
|
|
// the SU45 with AutoRelay=Optional but no FieldShuntSwitch: the switch is the old one, off hands the shunting to the
|
|
// second controller, and the start-up (as the AI) leaves it off
|
|
scenario scenario{"traction/field shunting switch/su45 optional alone", motion() + traction()};
|
|
scenario.train().add(definition::fiz("su45_v2/301d").set("Cntrl", "AutoRelay", "Optional"), 1);
|
|
scenario.add("bdhpumn_v3/bdhpumn");
|
|
REQUIRE(scenario.start_up());
|
|
auto &su45{scenario.driver().controlling};
|
|
REQUIRE(su45.AutoRelayType == 2);
|
|
REQUIRE_FALSE(su45.FieldShuntSwitch);
|
|
CHECK_FALSE(su45.AutoRelayFlag);
|
|
scenario.get_going();
|
|
scenario.full_power(120.0);
|
|
CHECK(su45.IsMainCtrlMaxPowerPos());
|
|
CHECK(su45.StLinFlag);
|
|
// over 50 km/h: the relays don't shunt, the driver does
|
|
CHECK(su45.Vel > 50.0);
|
|
CHECK(su45.ScndCtrlPos == 0);
|
|
scenario.act("field shunting by hand");
|
|
CHECK(su45.IncScndCtrl(1));
|
|
scenario.wait(1.0);
|
|
CHECK(su45.ScndCtrlPos == 1);
|
|
scenario.check();
|
|
}
|