mirror of
https://github.com/MaSzyna-EU07/maszyna.git
synced 2026-11-27 21:45:16 +01:00
* fix(ai): the driver tells of standing with its pantographs up and no voltage An AI driver of an electric vehicle standing past the end of the overhead wire, or under a wire switched off, never gets out of Prepare_engine: the voltage PrepareEngine() waits for doesn't come. It waited without a word (eu07/maszyna#421, L053 poranek with an ET21 on TME222158). Now it says so in the log, once per episode, with the vehicle's name and position, telling a missing wire (no raised pantograph found one) from a wire without voltage. It keeps trying, so towed back under the wire or with the power switched on the vehicle still gets prepared. The decision is ai_power (vehicle/aipower), in the core library with unit tests; scenario case et21_td_no_wire_reports puts an ET21 on a track of its own with no wire next to td.scn. * refactor(ai): the power stall report without Sonar issues stall::none becomes stall::not_stalled (none shadowed a global enumerator), using enum in check(), and an explicit cast of the pantograph count. No change in behaviour. * fix(ai): the power stall report is a traction log line It went out as a generic error, so a scenery that keeps its wire off on purpose couldn't mute it with logs.filter like the other traction lines.
424 KiB
424 KiB