On the electric locomotives the lamp of the open line contactors tells the start can be made, so it goes out with the start cut off by the pressure switch. The diesel-electric SU45 and SU46 (the only diesel-electrics with the lamp) use it just to show the contactors are open, but it went out the same way: with too low a pressure in the main pipe the contactors were open and the lamp out. Once the pressure came back with the master controller past the first position, the contactors stayed open, as they should, and the lamp lit up on a power position, which looked like the lamp working the other way round. On the diesel-electrics TMoverParameters::LineContactorsLampLit() now follows the contactors alone; the electric locomotives and the other main circuit lamps are unchanged. Tests: tests/unit/test_line_contactors.cpp, on a locomotive made after the SU46.
47 lines
2.6 KiB
JSON
47 lines
2.6 KiB
JSON
{
|
|
"_comment": "Diesel-electric locomotive made after the SU46 (303D): the line contactors close on the first power position of the master controller, the pressure switch (on by default) opens them with too low a pressure in the main pipe or the brakes applied.",
|
|
"Param": { "Category": "train", "M": 105000, "Mred": 15000, "Vmax": 120, "PWR": 1400, "SandCap": 400 },
|
|
"Dimensions": { "L": 18.99, "H": 4.292, "W": 2.904, "Cx": 0.3 },
|
|
"Wheels": { "D": 1.1, "AIM": 4000, "Tw": 1.435, "Axle": "Co'Co'", "Ad": 1.75, "Bd": 10.3, "Rmin": 100 },
|
|
"Brake": {
|
|
"BrakeValve": "LSt", "NBpA": 4, "MBF": 85.0, "MaxBP": 4.4, "LocMaxBP": 4.4, "MaxASBP": 1.3, "RM": 0.71, "BCN": 12, "BCR": 0.114,
|
|
"BCD": 0.06, "BCM": 5.84, "HiPP": 5, "LoPP": 3.5, "Vv": 0.9, "MinCP": 7, "MaxCP": 8.5, "CompressorSpeed": 0.05, "BCS": 1, "BSA": 2,
|
|
"BM": "P10-Bgu", "CompressorPower": "Converter", "BVV": 200, "BRE": 0.8
|
|
},
|
|
"BuffCoupl": { "CType": "Screw", "kB": 9200, "DmaxB": 0.15, "FmaxB": 740, "kC": 4800, "DmaxC": 0.15, "FmaxC": 780, "beta": 0.58, "AllowedFlag": 103 },
|
|
"Cntrl": {
|
|
"BrakeHandle": "FV4a", "LocBrakeHandle": "FD1", "BrakeSystem": "Pneumatic", "BDelay1": 15, "BDelay2": 6, "BDelay3": 36, "BDelay4": 32,
|
|
"ASB": "Manual", "LocalBrake": "PneumaticBrake", "MCPN": 15, "SCPN": 4, "AutoRelay": "Yes", "IniCDelay": 0.5, "SCDelay": 0.1,
|
|
"BrakeDelays": "GPR", "ConverterStart": "Automatic", "ConverterStartDelay": 10
|
|
},
|
|
"Light": { "Light": "Generator", "LGeneratorEngine": "ElectricSeriesMotor", "LMaxVoltage": 110, "LMaxCurrent": 100 },
|
|
"Engine": {
|
|
"AIM": 1.6, "EngineType": "DumbDE", "Trans": "18:62", "Ftmax": 317000, "Flat": 0, "Vhyp": 15.0, "Vadd": 3.8, "Cr": 1.0, "RelayType": 46,
|
|
"OilMinPressure": 0.055, "OilMaxPressure": 0.6, "WaterMinTemperature": 40, "WaterMaxTemperature": 92, "WaterCoolingTemperature": 76,
|
|
"HeatKW": 0.068599, "HeatKV": 0.3, "HeatKFE": 1, "HeatKFS": 87.76269, "HeatKFO": 26.72716, "HeatKFO2": 57.72
|
|
},
|
|
"Circuit": { "CircuitRes": 0.01, "ImaxLo": 3300, "IminLo": 2500 },
|
|
"_power": "rows: engine speed [rpm], power [kW], generator voltage limit, current limit, one per master controller position",
|
|
"WWList": {
|
|
"Size": 15,
|
|
"rows": [
|
|
[696, 0, 0, 0],
|
|
[696, 0, 0, 0],
|
|
[696, 80, 350, 1000],
|
|
[696, 80, 350, 1000],
|
|
[763, 214, 455, 1400],
|
|
[830, 321, 500, 1600],
|
|
[897, 428, 545, 1800],
|
|
[964, 535, 590, 2000],
|
|
[1031, 642, 635, 2200],
|
|
[1098, 748, 680, 2400],
|
|
[1165, 855, 725, 2600],
|
|
[1232, 962, 770, 2800],
|
|
[1299, 1069, 815, 3000],
|
|
[1366, 1176, 865, 3200],
|
|
[1433, 1283, 910, 3400],
|
|
[1500, 1390, 960, 3600]
|
|
]
|
|
}
|
|
}
|